42 CLIMATE 5000 RAC SINGLE SPLIT (R32) – 6720894076 (2019/08)
Troubleshooting
2.Field Maintenance Refrigerant Circuit Others
Possible causes of trouble
Dirty evaporator coil
Insufficient air through evaporator coil
Overcharge of refrigerant
Dirty or partially blocked condenser
Air in refrigerant cycle
Air flow circulation not correct
High temperature at condenser
Insufficient condens flow
Broken compressor internal parts
Inefficient compressor
Expansion valve obstructed
Expansion valve or capillary tube stucked
Leaking power element on expansion valve
Poor installation of feeler bulb
Insufficient cooling load
Loosen bolts or screws
Packing rest in the unit
Poor capacity
Contact with other components like pipe or plate
Unit will not start
Compressor does not start - Only fan runs
Compressor and condenser (outdoor) fan will
not start
Evaporator (indoor) fan will not start
Condenser (Outdoor) fan will not start
Unit runs, but shortly stops
✩ ✩ ✩ ✩
Compressor short-cycles due to overload
✩ ✩
High discharge pressure
✩ ✩ ✩ ✩ ✩ ✩
Low discharge pressure
✩
High suction pressure
✩ ✩ ✩ ✩
Low suction pressure
✩ ✩ ✩ ✩ ✩
Unit runs continuously but insufficient cooling
✩ ✩ ✩ ✩ ✩ ✩ ✩ ✩
Too cool
Compressor is noisy
✩ ✩ ✩ ✩ ✩
Horizontal louver can not revolve
Test method / remedy
Clean coil
Check fan
Change charged refrigerant volume
Clean condenser or remove obstacle
Purge, evacuate and recharge
Check the air flow for obstacles
Check the air flow for obstacles
Check the drain pipe
Check the compressor and replace if defect
Check the compressor operation
Check the expansion valve and replace if defect
Check the expansion valve and replace if defect
Check the expansion valve and replace if defect
Fix feeler bulb
Check the heat calculation
Tighten bolts or screws
Remove packing material
Check the building load calculation
Check if the compressor is touching another component and
correct
Table 16.