Delivery of air which contains a high dust load, e.g., extraction of saw
dust
Conveying of flammable gases/particles
Use of the fan units as safety-related components or for the assumption
of safety-relevant functions
80 mm
80mm
1 2
1 2
3
3
Machine
Air outlet space
Air suction area
Fig. 4-1: Fan units installation area, minimum distance
Consider the minimum distance of the air supply when designing the ma‐
chine.
Liquid cooling
Liquid-cooled energy storage devices may only operated on a closed coolant
circuit with heat exchanger. The coolant flow direction can be arbitrarily se‐
lected.
Expand the cooling circuit with anticorrosive. Please observe the information
in the project planning manual.
DOK-MOTOR*-MSK********-PR··-··-P, "Synchronous Servomotors MSK".
12/57
About this product
MSK Synchronous Servomotors
Bosch Rexroth AG R911325169_Edition 03