EasyManua.ls Logo

Bosch Rexroth SM 12 - Removal of a Hydraulic Operation H200 or H400

Bosch Rexroth SM 12
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal of a hydraulic operation H200 or 7.7
H400
Removal of the hydraulic cover
Remove the 2 mounting screws (4 mm socket wrench).
Remove :
the cover,
the o-ring.
Reassembly:
replace the cover o-ring,1.
reassemble parts in reverse order.2.
torque for mounting screws : 5 ± 10% N.m.3.
The control block does not need to be removed from the machine to
perform this operation.
DANGER
Oil pressure
Machine off:
place all of the machine’s actuators connected to the control block in f
neutral position,
release stored pressure by operating all the spools. f
NOTICE
Environment damages risk
Install a vacuum pump on the tank to limit oil leakage during this f
operation.
Collect possible leaks with a suitable receptacle. f
RE 64122-S/06.2011 | Type SM 12 Bosch Rexroth AG 27/30
Distribution element repair procedure

Related product manuals