5.7.1 To remove aqua sensor
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers.
1. Remove parts for bottom front accesssection 5.1.4.1.
2. If needed for access, remove power module section
5.3.2.2
3. Lift up housing latch, twist aqua sensor counter-clockwise
(ccw) and pull aqua sensor out from sump.
5.7.2 To install aqua sensor
1. Insert aqua sensor into sump with pc board vertical, then
twist clockwise (cw).
TIP: Apply some rinse-aid onto the aqua sensor O-
ring to lubricate it for easier installation.
5.8 Water inlet control
The water inlet control is easily accessed from the left side of the
dishwasher. It includes a condensation vent, so there’s no
separate condensation tube. The water inlet, sump and drain
hoses all connect to it.
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers.
1. Disconnect & pull out dishwashersection 5.1.5.1.
2. Remove lower rack (below left). If more space is
needed, remove the upper rack as well.
3. Unscrew condensation vent cap ccw (counterclockwise)
from inside of tank (below right).
4. Loosen hose clamp (1) from water inlet hose (2) and pull
water inlet hose from water inlet (3, below).
5. Pull out drain (4) and sump (5) hoses from water inlet
control (below).