Location 708 - 715
Zone Allocations For Area 3
Location 716 - 723
Zone Allocations For Area 4
Location 724 - 755
User Code Area Assignment
Location 724 725 726 727 728 729
User Code 1
0
User Code 2
0
User Code 3
0
User Code 4
0
User Code 5
0
User Code 6
0
Location 730 731 732 733 734 735
User Code 7
0
User Code 8
0
User Code 9
0
User Code 10
0
User Code 11
0
User Code 12
0
Location 736 737 738 739 740 741
User Code 13
0
User Code 14
0
User Code 15
0
User Code 16
0
User Code 17
0
User Code 18
0
Location 742 743 744 745 746 747
User Code 19
0
User Code 20
0
User Code 21
0
User Code 22
0
User Code 23
0
User Code 24
0
Location 748 749 750 751 752 753
User Code 25
0
User Code 26
0
User Code 27
0
User Code 28
0
User Code 29
0
User Code 30
0
Location 754 755
User Code 31
0
User Code 32
0
Location 756
Serial Printer Baud Rate
Location 757
Dialler Lockout Count
(V1.40+)
Location 760 - 763
Safecom – RF Fail (V2.00+)
Location 764 - 767
Safecom – Telco Fail (V2.00+)
Location 768 - 771
Safecom – RF Jamming (V2.00+)
Location 708 = Zone 1 LED – Area 3 Codepad
Location 709 = Zone 2 LED – Area 3 Codepad
Location 710 = Zone 3 LED – Area 3 Codepad
Location 711 = Zone 4 LED – Area 3 Codepad
Location 712 = Zone 5 LED – Area 3 Codepad
Location 713 = Zone 6 LED – Area 3 Codepad
Location 714 = Zone 7 LED – Area 3 Codepad
Location 715 = Zone 8 LED – Area 3 Codepad
708 709 710 711 712 713 714 715
0 0 0 0 0 0 0 0
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8
Location 716 = Zone 1 LED – Area 4 Codepad
Location 717 = Zone 2 LED – Area 4 Codepad
Location 718 = Zone 3 LED – Area 4 Codepad
Location 719 = Zone 4 LED – Area 4 Codepad
Location 720 = Zone 5 LED – Area 4 Codepad
Location 721 = Zone 6 LED – Area 4 Codepad
Location 722 = Zone 7 LED – Area 4 Codepad
Location 723 = Zone 8 LED – Area 4 Codepad
716 717 718 719 720 721 722 723
0 0 0 0 0 0 0 0
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8
0 = User Code Not Assigned
1 = User Code Assigned To Area 1
2 = User Code Assigned To Area 2
4 = User Code Assigned To Area 3
8 = User Code Assigned To Area 4
2
1 = 300 Baud
2 = 600 Baud
3 = 1200 Baud
4 = 2400 Baud
0
0 = No Lockout / 1 - 15 = Number Of Times Dialler Operate Till Lockout
3 5 3 1
Location 760 = 762 = Contact ID Event Code (Hundreds/Tens/Units)
Location 763 = Dialler Channel (Point ID = 30 Hex / 48 Decimal)
3 5 1 1
Location 764 = 766 = Contact ID Event Code (Hundreds/Tens/Units)
Location 767 = Dialler Channel (Point ID = 31 Hex / 49 Decimal)
3 4 4 1
Location 768 = 770 = Contact ID Event Code (Hundreds/Tens/Units)
Location 771 = Dialler Channel (Point ID = 32 Hex / 50 Decimal)
18 Solution-16/Solution-16
Safecom
Quick Reference Guide
SOL 16 SAFECOM QUICK REF GUIDE.DOC.DOC Bosch Security Systems Pty Limited