XI. Adjust External Siren Beep Volume for Key Fob Arm/Disarm
When you arm/disarm the system via a remote key fob, the external siren beeps briefly
to acknowledge this.
You can adjust the volume of these beeps (0 = no beeps, 15 = loudest beeps;
default = 13):
1. Enter programming mode: [ 1 2 3 4 # ]
2. Go to the location for Speaker Beep Volume: [ 4 9 1 # ]
3. Select a volume, e.g., no beeps: [ 0 * ]
4. Save and exit: [ 9 6 0 # ]
XII. Strobe Indication for Key Fob Arm/Disarm & Assign Key Fob
Button to Arm Stay Mode 1
If you still wish the strobe light to indicate when you arm/disarm via remote key fob, you
can program that feature in; additionally, you can program the fourth button on the remote
key fob to be able to arm the system in Stay Mode 1 — both features are stored at the
location for System Options 1.
1. Enter programming mode: [ 1 2 3 4 # ]
2. Go to the location for System Options 1: [ 4 9 2 # ]
3. Change the 1 to a 13: [ 13 * ]
4. Save and exit: [ 9 6 0 # ]
Options
• Default = 1
• Strobe Indication via Remote Arm/Disarm = 4
• Button 4 Stay Mode 1 = 8
Thus, 1 + 4 + 8 = 13
XIII. Add/Delete RF Device (Wireless Zones)
If you need to add RADION PIR detectors and other wireless RF devices, you can do so
using the following installer code operation:
1. Make sure you have assigned the RADION receiver.
2. Enter the RF device installer code operation: [ 1 2 3 4 0 # ]
3. Enter the zone number (1 - 16) that you wish to assign the RF device to, e.g.: [ 9 # ]
4. Enter the nine-digit RFID number on the RF device, e.g.: [ 1 2 3 4 5 6 7 8 9 # ]
5. Specify the RF zone option (can be left as 0 = All, or as 1 = Input 1): [ 0 # ]
Page !10 of !12