XI. Adjust External Siren Beep Volume for Key Fob Arm/Disarm
When you arm/disarm the system via a remote key fob, the external siren beeps briefly
to acknowledge this.
You can adjust the volume of these beeps (0 = no beeps, 15 = loudest beeps;
default = 13):
1. Enter programming mode: [ 1 2 3 4 # ]
2. Go to the location for Speaker Beep Volume: [ 4 9 1 # ]
3. Select a volume, e.g., no beeps: [ 0 * ]
4. Save and exit: [ 9 6 0 # ]
XII. Strobe Indication for Key Fob Arm/Disarm & Assign Key Fob
Button to Arm Stay Mode 1
If you still wish the strobe light to indicate when you arm/disarm via remote key fob, you
can program that feature in; additionally, you can program the fourth button on the remote
key fob to be able to arm the system in Stay Mode 1 both features are stored at the
location for System Options 1.
1. Enter programming mode: [ 1 2 3 4 # ]
2. Go to the location for System Options 1: [ 4 9 2 # ]
3. Change the 1 to a 13: [ 13 * ]
4. Save and exit: [ 9 6 0 # ]
Options
Default = 1
Strobe Indication via Remote Arm/Disarm = 4
Button 4 Stay Mode 1 = 8
Thus, 1 + 4 + 8 = 13
XIII. Add/Delete RF Device (Wireless Zones)
If you need to add RADION PIR detectors and other wireless RF devices, you can do so
using the following installer code operation:
1. Make sure you have assigned the RADION receiver.
2. Enter the RF device installer code operation: [ 1 2 3 4 0 # ]
3. Enter the zone number (1 - 16) that you wish to assign the RF device to, e.g.: [ 9 # ]
4. Enter the nine-digit RFID number on the RF device, e.g.: [ 1 2 3 4 5 6 7 8 9 # ]
5. Specify the RF zone option (can be left as 0 = All, or as 1 = Input 1): [ 0 # ]
Page !10 of !12

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)