Learning in wireless keyfob to the Solution 3000
Add or Delete RF Wireless Keyfob
Add the Keyfob
Notice! Set RF receiver as WE800EV2 or RADION receiver through the menu [3][5][1].
Enter the Master Code,
followed by [1] and the
[#] key (for example,
[25801#]).
Enter [#] key to
confirm the operation,
or press [*] to cancel
Keyfob RFID displays. The letter “M” appears in
the top right corner of the display indicating it is
in manual mode
- In manual mode, enter the 9-digit RADION
keyfob RFID, followed by the [#] key.
- Or press [*] key to switch into auto mode to
configure RADION or RE012EU keyfobs. The
letter ‘A’ should appear in the top right corner
of the display indicating it is in automatic mode.
Hold button 1 or 2 of the keyfob till codepad
displays RFID number. Press [#] key to confirm.
4
5
Choose a user number
then press the [#] key
6
Press menu [-]
to exit
1
2
Choose keyfob then
press the [#] key.
3
Delete the Keyfob
Enter the Master Code,
followed by [1] and
the [#] key
1
Choose a user number
then press the [#] key
2
Choose keyfob then
press the [#] key.
3
Press the [*] key to blank the
RFID and then press the [#]
to accept
4
Press menu [-] to exit.
5

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)