Page 1 from 45 6 720 887 546 “SM FP_ErP LPP/MPP Europe 2018/05 en”
LOW NOX INSTANTANEOUS
GAS WATER HEATER
ROOM SEALED FAN ASSISTED / PRESSURIZED
GAS WATER HEATER
FOR INDOOR INSTALLATION
TRAINING AND SERVICE INFORMATION FOR AFTER SALES
This document is restricted to exclusive use by the official service partners. Each
country should adapt the manual and its contents to the available range.

Other manuals for Bosch T5700S 15 D 23

Questions and Answers

  • J
    jasonandersonSep 18, 2025
    What to do if my Bosch Water Heater indicates a gas valve wrong connection?
    • S
      Scott RamosSep 18, 2025
      If a safety solenoid from the gas valve is disconnected, it indicates a gas valve wrong connection. The error is resolved by performing a manual reset.
  • W
    williamespinozaAug 25, 2025
    What to do if my Bosch Water Heater has exhaust blockage?
    • J
      Jordan GreenAug 25, 2025
      If the fan speed and/or consumption detect a pressure above normal operating conditions on the exhaust, check configuration parameters like AS (altitude), F9 (flue exhaust code), AP (appliance power), etc.
  • S
    Steven ReedAug 25, 2025
    What to do if my Bosch Water Heater shows temperature limiter or thermal fuse opened circuit?
    • T
      Todd HooverAug 26, 2025
      This error occurs if the temperature limiter detects a temperature over 85ºC, or if the thermal fuse contact opens (192ºC) due to overheating and malfunction of the temperature limiter. The error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • T
    Toni MoralesAug 26, 2025
    Why does my Bosch Water Heater display a water flow signal over specified maximum value?
    • C
      Cassandra McclainAug 27, 2025
      This error occurs when the water flow exceeds 22 l/min. The error is resolved when the water flow is below this value again.
  • R
    Robert RussellSep 22, 2025
    What causes an exhaust blockage error in my Bosch T5700S 15 D 23?
    • C
      Chloe MckeeSep 22, 2025
      If pressure above normal operating conditions is detected, it indicates an exhaust blockage. The error is resolved by performing a manual reset.
  • N
    Nicole HendrixSep 23, 2025
    What does MCU RAM DC internal error mean for my Bosch T5700S 15 D 23?
    • S
      stoutjenniferSep 23, 2025
      If voltage is too low (less than 70 V ac), it triggers an MCU RAM DC (micro controller) internal error. The error is resolved by performing a manual reset.
  • M
    martinheatherSep 9, 2025
    What does it mean when my Bosch T5700S 15 D 23 Water Heater displays MCU RAM DC (micro controller) internal error?
    • M
      Michael Harper DDSSep 10, 2025
      Check if the voltage is too low (less than 70V AC). This error is resolved by a manual reset. If the voltage is okay and the error persists, replace the control unit.
  • J
    justin86Sep 12, 2025
    Why does my Bosch T5700S 15 D 23 Water Heater show an error related to the temperature limiter or thermal fuse?
    • B
      Bridget RandolphSep 12, 2025
      If the temperature limiter detects a temperature over 85ºC, it causes the temperature limiter or thermal fuse to open the circuit. This error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • C
    Cheryl RichardsonSep 3, 2025
    What to do if my Bosch T5700S 15 D 23 Water Heater displays an internal checking failure?
    • B
      Barbara SmithSep 3, 2025
      This error is resolved by a manual reset. If the error persists, replace the control unit.
  • J
    Justin DavisSep 1, 2025
    What to do if my Bosch Water Heater remote controller removes the error code 5 times continuously within 15mins?
    • S
      Sara ChenSep 1, 2025
      This error is resolved by a manual reset.

Summary

3. Installation

4. Components Overview

4.2 Heat cell with burner pipes

4.3 Gas manifold

4.6 Heat Exchanger

4.10 Water Flow Sensor

4.11 Ignition electrode

1.12 lonization electrode

5. Working Principle; Electric Measurements

Power reduction in case of high temperature risk

Explains how the appliance reduces power to prevent overheating.

ECU Overview (MPP)

ECU Overview (LPP)

6. Service

7. Diagnostic Mode

8. Gas Power Adjustment

9. Combustion Power Adjustments

10. Maintenance

11. Trouble Shooting

Water Temperature Sensor Errors

Troubleshooting codes related to defective water temperature sensors.

Box Temperature Protection Errors

Details errors related to appliance box temperature exceeding limits.

Air Temperature Sensor Errors

Troubleshooting for open circuit errors in the air temperature sensor.

Fan Signal Errors

Error code for when no fan feedback signal is received.

Water Flow and Exhaust Errors

Codes for excessive water flow or exhaust blockage issues.

Over-temperature and Inlet Sensor Errors

Errors related to outlet over-temperature or inlet water sensor defects.

Temperature Limiter;Fuse & Safety Timeout Errors

Errors for temperature limiter, thermal fuse, or no ionization during safety time.

Bosch T5700S 15 D 23 Specifications

General IconGeneral
Voltage208/240 V
ThermostatElectronic
CategoryTankless
Water Connection3/4" NPT
CapacityTankless
Heating elementCopper
PhaseSingle Phase
Temperature Range30-60 °C