C
Cheryl RichardsonSep 3, 2025
What to do if my Bosch T5700S 15 D 23 Water Heater displays an internal checking failure?
- BBarbara SmithSep 3, 2025
This error is resolved by a manual reset. If the error persists, replace the control unit.
What to do if my Bosch T5700S 15 D 23 Water Heater displays an internal checking failure?
This error is resolved by a manual reset. If the error persists, replace the control unit.
Why does my Bosch T5700S 15 D 23 show over-temperature detected?
The control unit might be detecting an outlet water temperature exceeding 85ºC. This error is resolved by a manual reset.
What to do if my Bosch Water Heater remote controller removes the error code 5 times continuously within 15mins?
This error is resolved by a manual reset.
Why does my Bosch T5700S 15 D 23 use the wrong gas type?
If the appliance obtains an output higher than expected, it indicates the wrong gas type is being used. A manual reset should resolve this error.
What does it mean when my Bosch T5700S 15 D 23 Water Heater displays an ionization error?
If ionization is detected without heat demand, it results in an error. Perform a manual reset to resolve it.
What to do if my Bosch Water Heater shows leakage on gas valve?
If ionization is present for more than 4 seconds, it indicates a leakage on the gas valve. Resetting the system manually should resolve this issue.
Why does my Bosch T5700S 15 D 23 Water Heater have ionization loss?
This issue occurs when the ionization signal is lost 3 consecutive times. A manual reset should resolve the error.
What to do if my Bosch Water Heater shows a gas valve wrong connection?
If a safety solenoid from the gas valve is disconnected, the error can be resolved by a manual reset.
Why does my Bosch Water Heater display a water flow signal over specified maximum value?
This error occurs when the water flow exceeds 22 l/min. The error is resolved when the water flow is below this value again.
What to do if my Bosch Water Heater shows temperature limiter or thermal fuse opened circuit?
This error occurs if the temperature limiter detects a temperature over 85ºC, or if the thermal fuse contact opens (192ºC) due to overheating and malfunction of the temperature limiter. The error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
Voltage | 208/240 V |
---|---|
Thermostat | Electronic |
Category | Tankless |
Water Connection | 3/4" NPT |
Capacity | Tankless |
Heating element | Copper |
Phase | Single Phase |
Temperature Range | 30-60 °C |
Explains how the appliance reduces power to prevent overheating.
Troubleshooting codes related to defective water temperature sensors.
Details errors related to appliance box temperature exceeding limits.
Troubleshooting for open circuit errors in the air temperature sensor.
Error code for when no fan feedback signal is received.
Codes for excessive water flow or exhaust blockage issues.
Errors related to outlet over-temperature or inlet water sensor defects.
Errors for temperature limiter, thermal fuse, or no ionization during safety time.