Page 1 from 45 6 720 887 546 “SM FP_ErP LPP/MPP Europe 2018/05 en”
LOW NOX INSTANTANEOUS
GAS WATER HEATER
ROOM SEALED FAN ASSISTED / PRESSURIZED
GAS WATER HEATER
FOR INDOOR INSTALLATION
TRAINING AND SERVICE INFORMATION FOR AFTER SALES
This document is restricted to exclusive use by the official service partners. Each
country should adapt the manual and its contents to the available range.

Other manuals for Bosch T5600S 12 D 23

Questions and Answers

  • J
    john81Sep 18, 2025
    What to do if my Bosch Water Heater indicates a gas valve wrong connection?
    • S
      Sarah NguyenSep 18, 2025
      If a safety solenoid from the gas valve is disconnected, it indicates a gas valve wrong connection. The error is resolved by performing a manual reset.
  • D
    Douglas LynchAug 25, 2025
    What to do if my Bosch Water Heater has exhaust blockage?
    • J
      jessica76Aug 25, 2025
      If the fan speed and/or consumption detect a pressure above normal operating conditions on the exhaust, check configuration parameters like AS (altitude), F9 (flue exhaust code), AP (appliance power), etc.
  • R
    rodriguezsherryAug 25, 2025
    What to do if my Bosch T5600S 12 D 23 shows temperature limiter or thermal fuse opened circuit?
    • L
      lewiskevinAug 26, 2025
      This error occurs if the temperature limiter detects a temperature over 85ºC, or if the thermal fuse contact opens (192ºC) due to overheating and malfunction of the temperature limiter. The error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • D
    Daniel PhamAug 26, 2025
    Why does my Bosch T5600S 12 D 23 Water Heater display a water flow signal over specified maximum value?
    • J
      Jason LambAug 27, 2025
      This error occurs when the water flow exceeds 22 l/min. The error is resolved when the water flow is below this value again.
  • E
    Erin GarciaSep 22, 2025
    What causes an exhaust blockage error in my Bosch T5600S 12 D 23?
    • M
      meghanguzmanSep 22, 2025
      If pressure above normal operating conditions is detected, it indicates an exhaust blockage. The error is resolved by performing a manual reset.
  • L
    Lindsey SimsSep 23, 2025
    What does MCU RAM DC internal error mean for my Bosch T5600S 12 D 23?
    • H
      Heather WallaceSep 23, 2025
      If voltage is too low (less than 70 V ac), it triggers an MCU RAM DC (micro controller) internal error. The error is resolved by performing a manual reset.
  • R
    Ryan MccartySep 9, 2025
    What does it mean when my Bosch Water Heater displays MCU RAM DC (micro controller) internal error?
    • J
      Joel PatelSep 9, 2025
      Check if the voltage is too low (less than 70V AC). This error is resolved by a manual reset. If the voltage is okay and the error persists, replace the control unit.
  • V
    Victoria McdonaldSep 12, 2025
    Why does my Bosch T5600S 12 D 23 show an error related to the temperature limiter or thermal fuse?
    • K
      Katie HamiltonSep 12, 2025
      If the temperature limiter detects a temperature over 85ºC, it causes the temperature limiter or thermal fuse to open the circuit. This error is resolved by manually resetting the system after the temperature limiter cools down and the contact closes again.
  • K
    Kara FigueroaSep 3, 2025
    What to do if my Bosch Water Heater displays an internal checking failure?
    • J
      Jennifer AndersenSep 3, 2025
      This error is resolved by a manual reset. If the error persists, replace the control unit.
  • D
    Donna VegaSep 1, 2025
    What to do if my Bosch T5600S 12 D 23 remote controller removes the error code 5 times continuously within 15mins?
    • K
      Kenneth HarrisonSep 1, 2025
      This error is resolved by a manual reset.

Summary

3. Installation

Appliance Wall Fixation

Provides requirements and checklist for securely mounting the appliance to the wall.

Water Connections

Checklist for ensuring correct water connections, pressure, and flow.

Gas Connection

Checklist for verifying correct gas type, pressure, and connections.

Appliance Performance Verification

Procedure for measuring water flow and temperature increase to verify performance.

4. Components Overview

Control Panel Overview

Explains the function of the control panel for user, installer, and technician operations.

Heat Cell and Burner Assembly

Describes the heat cell, burner, ignition/ionization electrodes, and gas manifold.

5. Working Principle and Electric Measurements

High Temperature Risk Power Reduction

Describes power reduction strategy to prevent overheating and scalding hazards.

6. Service Procedures

Service Mode Entry Procedure

Step-by-step guide to access and navigate the appliance's service mode.

MPP User Level Parameters

LPP Remote Parameters

Technician Service Mode Parameters

P4 Diagnostic Mode Parameters

Gas Power Adjustment

7. Maintenance Procedures

Bosch T5600S 12 D 23 Specifications

General IconGeneral
CategoryWater Heater
PhaseSingle Phase
CapacityTankless
ThermostatElectronic
Safety FeaturesOverheat Protection