Table 8 Faults
10 Technical information
10.1 Technical data
This appliance meets the requirements specified by the European Directives 2014/35/EC and 2014/30/EC.
Table 9 Technical characteristics
X Inside of storage tank with accumulated dirt. Drain the DHW cylinder and clean the inside.
Assess the water supply (for example, apply a
filter).
Carry out maintenance and re-fill the tank.
X Development of bacteria. Drain the DHW cylinder and clean it.
Disinfect the DHW cylinder.
X X Possible re-circulation system for drinking water,
excessive consumption from water taps or leak in
the hot water system.
Assess time necessary for reheating (Tab. 9).
Replace with another, in line with consumption.
Problem Cause Solutions
Technical characteristics Unit ...30
S...
...50
S...
...50... ...80
S...
...80
H...
...80... ..100
H..
...100..
.
...120..
.
General details
Capacity l 30 50 50 75 75 75 100 100 115
Weight with empty tank kg 12,7 17,6 15,5 22,9 19,1 20,1 24,9 24,9 27,4
Weight with full tank kg 42,7 67,6 65,5 97,9 94,1 95,1 124,9 124,9 142,4
Heat loss through casing kWh/
24h
0,69 0,95 0,8 1,34 1,52 1,13 1,51 1,4 1,58
Data relating to the water
Max. permissible operating
pressure
bar888888888
Water connections Pol. G ½” G ½” G ½” G ½” G ½” G ½” G ½” G ½” G ½”
Electrical details
Rated output W 1500 1500 1500 2000 1500 2000 1500 2000 2000
Heating time (T-50 °C) 1h25 2h18 2h12 2h35 2h59 2h28 3h57 3h16 3h45
Supply voltage VAC 230 230 230 230 230 230 230 230 230
Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
Single phase electric current A 6,5 6,5 6,5 8,7 6,5 8,7 6,5 8,7 8,7
Power cord HO5VV-F 3x1,0mm
2
or HO5VV-F 3x1,5mm
2
Protection class I I I I I I I I I
Type of protection IP24 IP24 IP24 IP24 IP24 IP24 IP24 IP24 IP24
Water temperature
Range of temperatures °C until
68 °C
until
66 °C
until
64 °C
until
68 °C
until
62 °C
until
68 °C
until
67 °C
until
62 °C
until
65 °C
173 / 242 172 / 240 173 / 242