Maintenance | 21US
6 720 646 951 (2011/09)Copyright
Using an ohmmeter to check for premature element failure
Fig. 12 Heating elements
On WH17 model, there is no middle element
Meter probes Ohm Readings
Outer to Outer 10.5 ± 0.6 Ohms
Middle to Middle 11.7 ± 0.8 Ohms
Inner to Inner 15.1 ± 1 Ohms
Tab. 8
Meter probes Ohm Readings
Outer to Outer 10.5 ± 0.6 Ohms
Middle to Middle 11.7 ± 0.8 Ohms
Inner to Inner 21.0 ± 1.2 Ohms
Tab. 9