EasyManua.ls Logo

Bosch TRONIC 5000C Pro - Page 21

Bosch TRONIC 5000C Pro
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance | 21US
6 720 646 951 (2011/09)Copyright
Using an ohmmeter to check for premature element failure
Fig. 12 Heating elements
On WH17 model, there is no middle element
Meter probes Ohm Readings
Outer to Outer 10.5 ± 0.6 Ohms
Middle to Middle 11.7 ± 0.8 Ohms
Inner to Inner 15.1 ± 1 Ohms
Tab. 8
Meter probes Ohm Readings
Outer to Outer 10.5 ± 0.6 Ohms
Middle to Middle 11.7 ± 0.8 Ohms
Inner to Inner 21.0 ± 1.2 Ohms
Tab. 9

Table of Contents