17
P12 /P15 /P18
4. Technical Specifications 4.
P15
Heating
Steam
Electric
Other data:
Dist. throughput (DIN 11916) max. l/hr(US gal/h) 120(31.7)
75(19.8)
Filter throughput l/h(US gal/h) 4000(1056)
4000(1056)
Filter surface, economy filter m
2
(ft
2
) 2.7(29.0)
2.7(29.0)
Weight without solvent: Slimline
Crossline
kg(lb)
kg(lb)
1240(2734)
1340(2954)
1240(2734)
1340(2954)
Weight with solvent: Slimline
Crossline
kg(lb)
kg(lb)
1770(3902)
1870(4123)
1770(3902)
1870(4123)
Floor space: Slimline
Crossline
m
2
(ft
2
)
m
2
(ft
2
)
2.3(24.8)
2.5(26.9)
2.3(24.8)
2.5(26.9)
Floor surface: ** Slimline
Crossline
m
2
(ft
2
)
m
2
(ft
2
)
1.41(15.2)
1.41(15.2)
1.41(15.2)
1.41(15.2)
Cage centrifugal force N(lb) 7300(1640)
7300(1640)
Floor load, stat. and dyn: Slimline
Crossline
N/m
2
(N/ft
2
)
N/m
2
(N/ft
2
)
17500(365)
18200(380)
17500(365)
18200(380)
Noise level dB (A) 60
60
Carbon filling, Slimsorba kg(lb) 13(28)
13(28)
Heat balance: *
Heat to dissipate
via cooling water ***:
kJ/cycle 19000
19000
Heat dissipated to the
surroundings *:
kJ/cycle 4500
4500
* Values apply to a standard 2-bath cycle, 1
st
bath low level for distillation at cooling water inlet
temperature + 12 °C (53.6 °F), cage housing outlet temperature 50 °C (122 °F), steam supply 4 – 5
bar (58 – 72.5 psi) overpressure saturated steam, ambient temperature 5 to + 40 °C (41 – 104 °F)
**
Portion of the floor surface for force transmission, see Installation Instructions, Point 5.3.1
***
Refers to water without any additives
Subject to change!
All values were taken under testing conditions and can deviate in practice!