25
P12 /P15 /P18
6. Operation 6.
6.1. First Startup
6.1
The BÖWE Customer Service department is responsible for carrying out the first startup.
Attention: Before opening the switch panel or removing paneling,
set the main switch to " 0".
6.1.1. Preparatory Work
Set up the supply systems (electrical current, cooling water, compressed air, steam and condensate
lines).
6.1.2. Filling Machine With Solvent
Use only stabilized, high-purity TETRACHLORETHENE (perc), in accordance with DIN 53978.
The amount of solvent needed is:
Machine P12 tank I: approx. 60 l /15.8 US gal
Machine P15 tank I: approx. 75 l /19.8 US gal
Machine P18 tank I: approx. 90 l /23.7 US gal
Machine P12 tank III: approx. 60 l /15.8 US gal
Machine P15 tank III: approx. 75 l /19.8 US gal
Machine P18 tank III: approx. 90 l /23.7 US gal
Total filling amount P12 for the 3-tank model: approx. 280 l / 73.9 US gal
Total filling amount P15 for the 3-tank model: approx. 330 l / 87.1 US gal
Total filling amount P18 for the 3-tank model: approx. 380 l / 100.4 US gal
For machines with 2 economy filters: + 40 l (10.5 US gal)
For machines with 2 economy filters and 1 cartridge filter: + 55 l (14.5 US gal)
Attention: Perc is a powerful fat solvent. Wear gloves when handling
perc and apply protective skin ointment to hands when done. Do not
smoke. If you get perc in your eyes, seek further medical care.
If there is no suction from the pump, pour approx. 5 liters (1.3 US gal)
of solvent into the button trap. Check that the direction of rotation is
correct.