26
P12 /P15 /P18
6. Operation 6.
Filling without emissions:
1 Solvent
2 Aeration
3 Water separator
4 Ball valve
707770-23-0
Execution:
Connect a hose (1) between the barrel and ball valve (4).
Connect gas displacement line (2) between the barrel and water separator (3).
Open the ball valve (4).
Start program P51:
+ + +
The tanks fill up, with one overflowing into the other.
Watch the level of the liquid in the tank at the sight-glass until the tanks 1 and 2 are full.
Stop program P51.
Fill tank 3 with program P67.
Fill tank 2 once more with program P51.
Stop and quit program P51:
+ + + +
Lift the suction pipe out of the barrel.
Close the ball valve (4).
Remove the hose connections to the barrel.
Put the screw cap on to the ball valve (4).
Close the barrel and store in accordance with regulations.
Depending on the filter you have, you may have to refill with solvent after you fill the filter!