Installation and Operation Instructions Document 1318F
H2372800F
WARNING
If the information in this manual is not
followed exactly, a re or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
nearby phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a qualied installer, service agency, or gas
supplier.
FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician,
qualied in hot water boiler and heater installation and maintenance. Improper installation and/or operation
could create carbon monoxide gas in ue gases which could cause serious injury, property damage, or
death. Improper installation and/or operation will void the warranty.
AVERTISSEMENT
Assurez-vous de bien suivres les instructions
données dans cette notice pour réduire au
minimum le risque d’incendie ou d’explosion
ou pour éviter tout dommage matériel, toute
blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ou ni
d’autres vapeurs ou liquides inammables dans
le à proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones dans le bâtiment vous vous
trovez.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le sservice des incendies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualié
ou par le fournisseur de gaz.
Installation and Operation
Instructions for
Wall-Mounted, Modulating
Gas, Condensing, Combination Boiler
Model FTCW
140,000 BTU/hr
199,000 BTU/hr
Natural Gas (NG) - Factory Conguration
Propane Gas (LP) - Field-Convertible
THE
FT
SERIES

Table of Contents

Other manuals for Bradford White FTCW140

Questions and Answers

  • J
    Jessica VanceAug 19, 2025
    Why is my Bradford White FTCW140 water not hot enough?
    • T
      Tiffany JenningsAug 20, 2025
      If the water from your Bradford White Boiler isn't hot enough, try the following: * Check that the temperature setting on the unit isn't set too low. * Make sure the filter in the cold water supply line isn't clogged. * Confirm that the gas supply type is correct for your unit. * Verify the supply and manifold gas pressures are within the specified ranges. * Ensure the water flow sensor with three wires is properly connected on top of the heat exchanger.
  • M
    miranda68Aug 21, 2025
    How to fix a Bradford White FTCW140 when the burner does not ignite?
    • U
      ugillAug 22, 2025
      If the burner in your Bradford White Boiler doesn't ignite when you open the hot water tap, there are several things to check: * Ensure the ON/OFF button on the Control Panel is ON. * If the Control Panel monitor is blank, verify the power cord is plugged in and the 4A fuses on the main controller are intact. * Confirm the unit is receiving water, as it activates with an inlet water flow exceeding 0 gpm. * Check that the cold and hot water lines aren't reversed. * Ensure both the cold water and gas supply lines are open. * Make sure the water lines aren't frozen.
  • S
    Sean ThompsonAug 25, 2025
    What to do if nothing is shown on the Bradford White Boiler control panel?
    • S
      Steven LeeAug 25, 2025
      If nothing is showing on the display control panel and no other components of your Bradford White Boiler are operating, consider these checks: * Ensure the service switch and/or circuit breaker to the boiler are turned on. * Confirm there is 120 Volts at the service switch. * Check if the ON/OFF POWER SWITCH (inside the boiler case) is turned on. * Verify there is 120 volts at the line voltage terminal block inside the boiler case. * Inspect the fuse and replace it if necessary.
  • H
    Holly AcevedoAug 26, 2025
    Why is my Bradford White FTCW140 water too hot?
    • J
      Jessica BrooksAug 26, 2025
      If the water from your Bradford White Boiler is too hot, consider these solutions: * Ensure that the temperature setting on the unit is not too high. * Make sure that the filter in the cold water supply line is not clogged with debris. * Ensure that the gas supply type is correct.
  • V
    Veronica WarrenAug 28, 2025
    How to fix hot water temperature fluctuations in my Bradford White FTCW140?
    • Y
      yprattAug 28, 2025
      If the hot water temperature from your Bradford White Boiler fluctuates at the tap, try these solutions: * Ensure that the filter in the cold water supply line is clean. * Make sure that the gas supply type is correct. * Check the supply gas pressure is sufficient.
  • M
    Manuel RodriguezAug 29, 2025
    What to do if Bradford White FTCW140 Boiler is working but the control panel is blank?
    • C
      Cynthia WilliamsAug 29, 2025
      If nothing is displayed on the control panel of your Bradford White Boiler, but the boiler is operating, it may be due to a loss of communication between the control and the display. Try these steps: * Check for loose connections and proper pin alignment/engagement on the Control's plug. * Cycle power off and on using the boiler power switch and check for operation.
  • X
    xrobinsonSep 1, 2025
    Why is my Bradford White Boiler making abnormal sounds?
    • M
      Michael BerrySep 1, 2025
      If you are hearing abnormal sounds from your Bradford White Boiler during operation: * A leak of combustion gas between the sealed chamber and exhaust tube inside the unit may be the cause; call a qualified service technician for evaluation. * Ensure that the venting termination complies with specifications, as improper venting termination may be the reason. * Check the supply gas pressure is sufficient, as insufficient gas pressure will cause unstable burner flame and noise.
  • K
    Kevin GriffinSep 3, 2025
    What does it mean when the temperature rises too quickly on my Bradford White FTCW140?
    • V
      Virginia EdwardsSep 3, 2025
      If the temperature rises too quickly in your Bradford White Boiler, it could be because the supply water temperature in the heat exchanger is rising faster than 2°F per second during the first two minutes the burner is on. This condition: * Automatically resets after a few minute delay or using manual reset on control panel. * If you see a 'TEMPERATURE SENSOR' message, follow the procedure for loose connections.
  • A
    Annette HallSep 4, 2025
    Why is my Bradford White FTCW140 display blank and the blower running at full speed?
    • J
      Jorge FlemingSep 5, 2025
      If nothing is showing on the display control panel and the blower is running at full speed on your Bradford White Boiler: * Check the wiring for a short circuit or incorrect wiring, as the control may not be receiving power. * Check the transformer connection to the control per the wiring diagram and check for 12V output of the transformer.
  • J
    johnsondavidSep 6, 2025
    Why does the blower keep running after combustion stops in my Bradford White Boiler?
    • B
      brownamySep 6, 2025
      If the blower in your Bradford White Boiler continues to operate after combustion stops, this is normal. The blower keeps operating for 1 minute to vent (exhaust) the flue gas from the chamber once the combustion has stopped.

Summary

SECTION 3 Safety Regulations

3.2 Safety Precautions and Proper Use

Provides essential safety guidelines for operation and handling of the appliance.

SECTION 4 Installation

Installation Site and Mounting

Covers boiler placement, clearances, and mounting bracket installation.

Gas Supply and Conversion Procedures

Guides on gas piping, pressure, setup, and fuel type conversion.

Plumbing and Electrical Systems

Covers water connections, pressure relief valves, and electrical wiring.

SECTION 5 Control Display and Operation

SECTION 6 Error Codes

6.1 Error Codes

Lists error codes, their descriptions, possible remedies, and recovery methods.

SECTION 7 Trouble Shooting

SECTION 8 Maintenance

SECTION 9 Installation Check

9.2 Final Check Lists

Lists critical checks to perform after installation is complete.

Bradford White FTCW140 Specifications

General IconGeneral
BrandBradford White
ModelFTCW140
CategoryBoiler
LanguageEnglish

Related product manuals