Installation and Operation Instructions Document 1318F
H2372800F
WARNING
If the information in this manual is not
followed exactly, a re or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
nearby phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a qualied installer, service agency, or gas
supplier.
FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician,
qualied in hot water boiler and heater installation and maintenance. Improper installation and/or operation
could create carbon monoxide gas in ue gases which could cause serious injury, property damage, or
death. Improper installation and/or operation will void the warranty.
AVERTISSEMENT
Assurez-vous de bien suivres les instructions
données dans cette notice pour réduire au
minimum le risque d’incendie ou d’explosion
ou pour éviter tout dommage matériel, toute
blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ou ni
d’autres vapeurs ou liquides inammables dans
le à proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones dans le bâtiment vous vous
trovez.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le sservice des incendies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualié
ou par le fournisseur de gaz.
Installation and Operation
Instructions for
Wall-Mounted, Modulating
Gas, Condensing, Combination Boiler
Model FTCW
140,000 BTU/hr
199,000 BTU/hr
Natural Gas (NG) - Factory Conguration
Propane Gas (LP) - Field-Convertible
THE
FT
SERIES

Table of Contents

Questions and Answers

  • J
    Jeffrey PenningtonAug 20, 2025
    Why is my Bradford White Boiler water not hot enough?
    • D
      Donna RiggsAug 20, 2025
      If the water from your Bradford White Boiler isn't hot enough, try the following: * Check that the temperature setting on the unit isn't set too low. * Make sure the filter in the cold water supply line isn't clogged. * Confirm that the gas supply type is correct for your unit. * Verify the supply and manifold gas pressures are within the specified ranges. * Ensure the water flow sensor with three wires is properly connected on top of the heat exchanger.
  • N
    Nathan McdonaldAug 22, 2025
    How to fix a Bradford White FTCW199 when the burner does not ignite?
    • L
      Leslie WoodAug 22, 2025
      If the burner in your Bradford White Boiler doesn't ignite when you open the hot water tap, there are several things to check: * Ensure the ON/OFF button on the Control Panel is ON. * If the Control Panel monitor is blank, verify the power cord is plugged in and the 4A fuses on the main controller are intact. * Confirm the unit is receiving water, as it activates with an inlet water flow exceeding 0 gpm. * Check that the cold and hot water lines aren't reversed. * Ensure both the cold water and gas supply lines are open. * Make sure the water lines aren't frozen.
  • A
    anna71Aug 25, 2025
    What to do if nothing is shown on the Bradford White FTCW199 control panel?
    • N
      njenningsAug 25, 2025
      If nothing is showing on the display control panel and no other components of your Bradford White Boiler are operating, consider these checks: * Ensure the service switch and/or circuit breaker to the boiler are turned on. * Confirm there is 120 Volts at the service switch. * Check if the ON/OFF POWER SWITCH (inside the boiler case) is turned on. * Verify there is 120 volts at the line voltage terminal block inside the boiler case. * Inspect the fuse and replace it if necessary.
  • K
    Kathy BakerAug 26, 2025
    Why is my Bradford White FTCW199 water too hot?
    • M
      michael09Aug 27, 2025
      If the water from your Bradford White Boiler is too hot, consider these solutions: * Ensure that the temperature setting on the unit is not too high. * Make sure that the filter in the cold water supply line is not clogged with debris. * Ensure that the gas supply type is correct.
  • V
    Vanessa HernandezAug 28, 2025
    How to fix hot water temperature fluctuations in my Bradford White FTCW199 Boiler?
    • J
      joshua80Aug 28, 2025
      If the hot water temperature from your Bradford White Boiler fluctuates at the tap, try these solutions: * Ensure that the filter in the cold water supply line is clean. * Make sure that the gas supply type is correct. * Check the supply gas pressure is sufficient.
  • J
    John PattersonAug 30, 2025
    What to do if Bradford White FTCW199 is working but the control panel is blank?
    • R
      Regina JacksonAug 30, 2025
      If nothing is displayed on the control panel of your Bradford White Boiler, but the boiler is operating, it may be due to a loss of communication between the control and the display. Try these steps: * Check for loose connections and proper pin alignment/engagement on the Control's plug. * Cycle power off and on using the boiler power switch and check for operation.
  • H
    Hector ChambersSep 1, 2025
    Why is my Bradford White Boiler making abnormal sounds?
    • J
      James FergusonSep 1, 2025
      If you are hearing abnormal sounds from your Bradford White Boiler during operation: * A leak of combustion gas between the sealed chamber and exhaust tube inside the unit may be the cause; call a qualified service technician for evaluation. * Ensure that the venting termination complies with specifications, as improper venting termination may be the reason. * Check the supply gas pressure is sufficient, as insufficient gas pressure will cause unstable burner flame and noise.
  • S
    Sherry ButlerSep 3, 2025
    What does it mean when the temperature rises too quickly on my Bradford White Boiler?
    • L
      Leah BryantSep 3, 2025
      If the temperature rises too quickly in your Bradford White Boiler, it could be because the supply water temperature in the heat exchanger is rising faster than 2°F per second during the first two minutes the burner is on. This condition: * Automatically resets after a few minute delay or using manual reset on control panel. * If you see a 'TEMPERATURE SENSOR' message, follow the procedure for loose connections.
  • Y
    ysuttonSep 5, 2025
    Why is my Bradford White FTCW199 Boiler display blank and the blower running at full speed?
    • K
      Kyle PageSep 5, 2025
      If nothing is showing on the display control panel and the blower is running at full speed on your Bradford White Boiler: * Check the wiring for a short circuit or incorrect wiring, as the control may not be receiving power. * Check the transformer connection to the control per the wiring diagram and check for 12V output of the transformer.
  • N
    nancysalazarSep 7, 2025
    Why does the blower keep running after combustion stops in my Bradford White Boiler?
    • R
      Ronald LopezSep 7, 2025
      If the blower in your Bradford White Boiler continues to operate after combustion stops, this is normal. The blower keeps operating for 1 minute to vent (exhaust) the flue gas from the chamber once the combustion has stopped.

Summary

Installation and Operation Instructions

What to Do If You Smell Gas

Immediate actions to take if a gas leak is detected, including safety steps.

Product Characteristics

Specifications

Details technical specifications for FTCW140 and FTCW199 models.

Safety Regulations

Safety Precautions and Proper Use

Crucial warnings and precautions for safe operation and potential hazards.

Installation

Location and Clearances

Guidelines for selecting installation location and required clearances from combustibles.

Combustion Air

Requirements for providing combustion air from room or ducted sources.

Venting (Exhaust)

Regulations and materials for safe and proper exhaust venting installation.

Air Supply and Vent Connections

Procedures for connecting air supply and vent pipes to the appliance.

Gas Supply and Piping

Guidelines for proper gas supply line sizing, installation, and connection.

Gas Supply Pressure

Specifications for maximum and minimum gas inlet pressures.

Natural Gas to Propane Conversion

Step-by-step instructions for converting the boiler from natural gas to propane.

Plumbing Guidelines

Standards for water connections, piping sizes, and zoning systems.

Pressure Relief Valve

Guidelines for installing and testing pressure relief valves for safety.

Control Display and Operation

Error Codes

Trouble Shooting

Maintenance

Installation Check

Bradford White FTCW199 Specifications

General IconGeneral
CategoryBoiler
BrandBradford White
ModelFTCW199
Fuel TypeNatural Gas
Thermal Efficiency80%