MODEL
5300
Premier Series
Universal Auto Changeover
Up to 3 Heat / 2 Cool Heat Pump or
2 Heat / 2 Cool Conventional Thermostat
USER
MANUAL
READ ALL INSTRUCTIONS
BEFORE PROCEEDING
Braeburn Systems LLC, as an Energy Star
partner has determined that this product
meets the Energy Star Guidelines developed
by the U.S. Environmental Protection Agency
& the U.S. Department of Energy for
maximum energy efficiency.
CONTENTS
1
2
QUICK REFERENCE
PROGRAMMING
USER SETTINGS
QUICK REFERENCE
1
3
4
ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING
SYSTEM Button: Selects AUTO (Heat/Cool), COOL, OFF,
HEAT or EMER.
PROG Button: Press to enter the program setup mode where
you can select the time, temperature and fan setting for each
program period. Scrolls backward between user/installer
setup screens.
HOLD Button: Enables or disables extended hold mode or
temporary program override.
RETURN Button: Press and hold for 4 seconds to enter the
user settings mode (see user manual). Scrolls between user/
installer setup screens. Returns unit to normal mode when
in program mode.
DAY/TIME Button: Enters time and day setting mode.
Selects individual days in program mode.
FAN Button: Selects AUTO, ON, CIRC (recirculate) and
PROG (program) modes.
RESET Button: Resets time, program and some user settings back to the factory default. See section 4 for a list of functions
that will return to their factory default settings after the RESET button is pressed.
Button: Turns on backlight for 10 seconds.
Button: Increases setting (time, temperature, etc.). Scrolls between option settings.
Button: Decreases setting (time, temperature, etc.). Scrolls between option settings.
1
1
2
3
4
5
6
7
9
10
model 5300 shown with cover open
8
9
7
1
6
2
3
4
5
10
8
2
3
+
Press and hold both buttons at the same time to view the outdoor temperature if an outdoor sensor is connected.

Other manuals for Braeburn 5300

Question and Answer IconNeed help?

Do you have a question about the Braeburn 5300 and is the answer not in the manual?

Braeburn 5300 Specifications

General IconGeneral
TypeProgrammable Thermostat
ChangeoverManual
Hold FeatureYes
Filter Change AlertYes
DisplayLCD
Power Source24 VAC
Stages2 Heat / 1 Cool
Programmability7-Day Programmable
Warranty5 Years

Summary

Quick Reference Guide

SYSTEM Button Function

Selects AUTO (Heat/Cool), COOL, OFF, HEAT or EMER modes.

PROG Button Function

Enters program setup mode for time, temperature, and fan settings.

HOLD Button Function

Enables or disables extended hold or temporary program override.

RETURN Button Function

Enters user settings mode or returns unit to normal mode from program mode.

DAY/TIME Button Function

Enters time and day setting mode or selects individual days in program mode.

FAN Button Function

Selects AUTO, ON, CIRC (recirculate), and PROG (program) fan modes.

RESET Button Function

Resets time, program, and some user settings to factory defaults.

Backlight Button

Turns on backlight for 10 seconds.

Adjustment Buttons

Increase/decrease settings or scroll between options.

Outdoor Sensor Check

Press and hold both adjustment buttons to view outdoor temperature.

Programming User Settings

Setting Current Time and Day

Establishes accurate time and day for proper program execution.

Setting Fan Control Modes

Configures fan operation for AUTO, ON, CIRC, or PROG modes.

Setting Thermostat System

Selects system mode: AUTO, COOL, OFF, HEAT, or EMER.

Configuring Thermostat User Options

Adjusts default settings for optimal system performance and user preference.

Setting Stage Differentials

Defines temperature changes required to activate heating/cooling stages.

Setting Filter Check Monitor

Sets interval for filter replacement or cleaning reminders.

Setting UV Light Monitor

Sets interval for UV bulb replacement reminders.

Setting Humidifier Pad Monitor

Sets interval for humidifier pad replacement reminders.

Setting Extended Hold Mode

Configures indefinite or timed hold for vacation or extended absence.

Setting Temporary Override Limit

Limits how much the thermostat can be adjusted from programmed set points.

Setting Temporary Override Time Limit

Defines how long manual temperature adjustments remain active.

Setting Keypad Lockout Code

Establishes a code to lock or unlock thermostat keypad access.

Setting Recirculating Fan Cycle

Configures the interval for intermittent air circulation.

Energy Saving Programs Overview

Tips and default settings for energy-efficient heating and cooling programs.

Residential 7 Day Defaults

Default program settings for a 7-day residential schedule.

Commercial 2 Event Defaults

Default program settings for a 2-event commercial schedule.

Residential 5-2 Day Defaults

Default program settings for weekday/weekend residential schedules.

Entering 7-Day Residential Programs

Instructions for programming individual days or the entire week.

Entering 5-2 Day Residential Programs

Instructions for programming weekday and weekend schedules separately.

Additional Operation Features

Set Temperature Review/Change (Non-Programmable)

Allows reviewing or changing set temperature in non-programmable mode.

Auto Changeover Mode Explanation

Details how the system automatically switches between heating and cooling.

Remote Indoor Sensor

Information on using a remote sensor for temperature sensing.

Remote Outdoor Sensor

Information on using a remote outdoor sensor for data display.

Temporary Program Override

Temporarily changes the program set temperature.

Extended Hold (Vacation) Mode

Bypasses the program schedule to hold a set point temperature.

Filter Check Monitor

Displays a reminder for filter replacement or cleaning.

UV Light Monitor

Displays a reminder for UV bulb replacement.

Humidifier Pad Monitor

Displays a reminder for humidifier pad replacement.

Keypad Lock/Unlock

Procedure to lock or unlock the thermostat keypad using a code.

Adaptive Recovery Mode (ARM)

Optimizes heating/cooling to reach set points near program times.

Recirculating Fan Feature

Improves air quality by circulating air through the filtration system.

Programmable Independent Fan

Allows continuous fan operation during selected time periods.

Compressor Protection

Automatic protection against short cycling and power outages.

Low Battery Detection

Monitors battery status and provides replacement alerts.

Troubleshooting Guide

Fan Continues Running After Cooling Off

Addresses residual cooling fan delay feature.

Thermostat Not Turning On System

Checks for OFF mode, compressor protection, and heat pump status.

Incorrect Heating/Cooling Operation

Troubleshoots system turning on wrong mode, possibly due to wiring.

Fan Runs Intermittently or When Off

Normal operation for recirculate mode.

System Turns On Before Setback End

Indicates Adaptive Recovery Mode may be active.

Frequent/Infrequent System Cycling

Adjusting temperature differential for performance.

Thermostat Not Following Programs

Checks time, day, override status, and hold mode.

No Automatic Heating/Cooling Switch

Verifies Auto Changeover selection and dead band settings.

Stage Activation Too Quick/Slow

Adjusting second/third stage differential settings.

Low Battery Indicator

Alert for battery replacement.

Constant Fan Operation

Checks fan settings (ON or PROG mode).

Cannot Set Temperature Below 45°F

Explains the lower limit of the thermostat's temperature range.

HI Temperature Display

Sensed temperature exceeds display range; cooling may be needed.

Room Too Warm or Too Cold

Guide to verify set point and make adjustments.

Thermostat Display Blank

Checks AC power and battery status; calls for service if needed.

Cannot Set Temperature Above 90°F

Explains the upper limit of the thermostat's temperature range.

Cannot Change Set Point

Troubleshoots keypad lockout and code entry.

Keypad Not Functioning

Checks if the keypad is locked.

LO Temperature Display

Sensed temperature below display range; heating may be needed.

Fan Runs Continuously

Verifies fan programming and wiring.

Unit Will Not Enter Program Mode

Checks if the thermostat is in non-programmable mode.

Temporary Override Limited

Checks user options for override limits.

Set Point Limit Reached

Checks installer options for set point limits.

System Turns On Ahead of Schedule

Adaptive recovery mode may be enabled.