HYDRAULIC SYSTEM
KUKJE MACHINERY CO., LTD.
142
4. CHECKING, DISASSEMBLING AND SERVICING
3) Hydraulic Pump for Three Point Hydraulic System
< Flometer connection and test preparation >
◈ Important
¾ When using a flowmeter other than a Branson
specified flometer, be sure to use the instructions
with that flowmeter.
¾ In this hook-up, there is no relief valve. Therefore
while testing, do not close the flowmeter loading
valve completely.
1. Open the hood, then remove the hood and
disconnect the battery grounding cord.
2. Remove the accelerator rod(1).
3. Remove the fuel filter retaining nut.
4. Disconnect the hydraulic delivery pipe(5).
5. Install the adaptor(7) to the hydraulic pump(3).
6. Reinstall the engine stop solenoid(4).
7. Reinstall the accelerator rod(1).
8. Connect the hydraulic test hose(6) to the
adapter61 and flowmeter inlet port.
9. Connect the another hydraulic test hose(8) to
flowmeter outlet port and transmission oil filling
port.
10. Open the flowmeter loading valve completely.
(Turn counterclockwise)
11. Start the engine and set the engine speed at
2600rpm.
12. Slowly close the loading valve to generate the
pressure approx. 13.7㎫ (140kgf/㎠, 1991psi).
13. Hold in this condition until oil temperature
reaches approx. 50℃ (122℉).
▷ Reference
9 Adapter is included in the adapter set.
*. PART NAME
1) Accelerator rod
2) Power steering delivery pipe
3) Hydraulic pump 4) Engine stop solenoid
5) Hydraulic delivery pipe
6) Hydraulic test hose 7) Adapter
8) Hydraulic test hose