12
Cleaning Cartridge / Replacement (see fig. F)
When the level indicator (15a) lights up permanently red, the remaining fluid in the
cartridge is sufficient for about 3 more cycles. When the level indicator blinks red, the
cartridge needs to be replaced (about every 3 weeks when used daily).
After having pressed the lift button (13) to open the housing, wait for a few seconds
before removing the used cartridge to avoid any dripping. Before discarding the used
cartridge, make sure to close the openings using the lid of the new cartridge, since the
used cartridge will contain contaminated cleaning solution.
The hygienic cleaning cartridge contains alcohol or isopropanol (specification see
cartridge), which once opened will naturally evaporate slowly. Each cartridge, if not used
daily, should be replaced after approximately 8 weeks to ensure optimal disinfection.
The cleaning cartridge also contains lubricants for the shaving system, which may leave
residual marks on the outer foil frame and the cleaning chamber of the Clean&Charge
Station. These marks can be removed easily by wiping gently with a damp cloth.
Accessories
Braun recommends changing your shaver’s Foil & Cutter cassette every 18 months to
maintain your shaver’s maximum performance.
Available at your dealer or Braun Service Centres:
• Foil & Cutter cassette: 92S/92B
• Cleaning cartridge Clean&Charge Station: CCR
• Braun Shaver cleaner spray
Battery removal
This appliance contains a rechargeable battery. Before disposing of the appliance,
disassemble the housing as shown, remove the rechargeable battery and recycle or
dispose of properly, according to local guidelines.
Caution: Disassembling the appliance will destroy it and invalidate the warranty.
Li-ion
Ser
ies 5
1
1
2
90892135_Series_9-2_NA_S6-48.indd 1290892135_Series_9-2_NA_S6-48.indd 12 27.05.16 10:1427.05.16 10:14
CSS APPROVED Effective Date 30May2016 GMT - Printed 29Jun2016 Page 12 of 48