EasyManua.ls Logo

Braun 5791 - Page 14

Braun 5791
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Unpleasant
smell from the
shaver head.
1. Shaver head is cleaned
with water.
2. Cleaning cartridge is in use
for more than 8 weeks.
1. When cleaning the shaver head with
water only use hot water and from
time to time some liquid soap
(without abrasive substances).
Remove Foil & Cutter cassette to let
it dry.
2. Change cleaning cartridge at least
every 8 weeks.
Battery
performance
dropped
significantly.
1. Shaver head is regularly
cleaned with water but not
lubricated.
2. Foil and cutter are worn
which requires more power
for each shave.
1. If the shaver is regularly cleaned
with water, apply a drop of light
machine oil on top of the foil once a
week for lubrication.
2. Replace Foil & Cutter cassette.
Shaving
performance
dropped
significantly.
1. Shaving system is
clogged.
2. Foil and cutter are worn.
1. Soak the Foil & Cutter cassette in
hot water with a drop of dish liquid.
Afterwards rinse it properly and tap
it out. Once dry apply a drop of light
machine oil on the foil.
2. Replace Foil & Cutter cassette.
Shaver turns
off with fully
charged
battery.
Foil and cutter are worn
which requires more power
than the motor can deliver.
The appliance turns off.
Replace Foil & Cutter cassette.
Regularly oil the shaving system,
especially when cleaning with water
only.
Shaver head is
damp.
1. Drain of the Clean&Charge
Station is clogged.
2. Cleaning cartridge has
been used for quite a
while.
1. Clean the drain with a wooden
toothpick.
2. The alcohol proportion has
decreased while the oil proportion
has increased. Remove residue
with a cloth.
CLEAN&CHARGE STATION
Cleaning does
not start when
pressing the
start button.
1. Shaver is not placed
properly in the
Clean&Charge Station.
2. Cleaning cartridge does
not contain enough
cleaning fluid (level
indicator blinks red).
3. Appliance is in stand-by
mode.
1. Insert shaver into the Clean&Charge
Station (contacts of the shaver
need to align with contacts in the
station).
2. Insert new cleaning cartridge.
3. Press start button again.
Increased
consumption of
cleaning fluid.
Drain of the Clean&Charge
Station is clogged.
Clean the drain with a wooden
toothpick.
Regularly wipe the tub clean.
91845282_Series_9-2_NA.indd 1491845282_Series_9-2_NA.indd 14 21.03.18 11:0121.03.18 11:01