73
TECHNICAL DATA
Chapter 10
Note: Different test values of IEC 60601-2-24 are marked in the table. At the test values no
dangerous disturbances occurred at the lower test values of IEC 60601-1-2.
Im
m
unity
tes
t
Guid
a
nc
e
a
nd
m
a
nufa
c
tur
er
’
s
d
ec
la
r
a
tio
n
–
elec
tr
o
m
a
g
netic
im
m
unity
T
he
Spa
ce
Syst
e
m is int
e
nde
d for use
in t
he
e
le
ct
roma
gne
t
ic e
nvironme
nt
spe
cifie
d be
low
.
T
he
cust
ome
r or t
he
use
r of t
he
Spa
ce
Syst
e
m or a
ny compone
nt
should a
ssure
t
ha
t
it
is use
d in such
a
n e
nvironme
nt
.
El
ec
tros
tati
c
di
s
c
h
arge
(ESD)
ac
c
ordi
n
g
I
EC
6
0
6
01
-
4
-
2
cont
a
ct
IE
C
6060
1-
1-
2:
±
6K
V
IE
C
6060
1-
2-
24:
±
8K
V
a
ir
IE
C
6060
1-
1-
2:
±
8K
V
IE
C
6060
1-
2-
24:
±
15K
V
±
6K
V
no dist
urba
nce
s
±
8K
V
st
op w
it
h a
la
rm
possible
±
8K
V
no dist
urba
nce
s
±
15K
V
st
op w
it
h a
la
rm
possible
Floors should be
w
ood,
concre
t
e
or ce
ra
mic t
ile
.
I
f floors a
re
cove
re
d w
it
h
synt
he
t
ic ma
t
e
ria
l,
t
he
re
la
t
ive
humidit
y should be
a
t
le
a
st
30 %.
El
ec
tros
tati
c
tran
s
i
en
t
/
bu
rs
t
ac
c
ordi
n
g
I
EC
610
0
0
-
4
-
4
±
2 kV
for pow
e
r
supply line
s
±
1 kV
for
input
/out
put
line
s
±
2K
V
±
1K
V
A/C
pow
e
r qua
lit
y should be
t
ha
t
of a
t
ypica
l comme
rcia
l or
hospit
a
l e
nvironme
nt
.
Su
rge
ac
c
ordi
n
g
I
EC
610
0
0
-
4
-
5
diffe
re
nt
ia
l mode
±
1K
V
common mode
±
2K
V
±
1K
V
±
2K
V
A/C
pow
e
r qua
lit
y should be
t
ha
t
of a
t
ypica
l comme
rcia
l or
hospit
a
l e
nvironme
nt
.
Power freq
uency
(50/60 Hz)
magnetic field
accordin
g IEC
61000-4-8
3
A/m
4
00
A/m
Power frequency magnetic
fields should be at levels
characteristic of a typical
location in a typical
commercial or hospital
environment.
Volt
a
ge
dips,
short
interruptions and
voltage variations
on power sup
p
ly
inpu
t
lines
according
I
EC
61000-
4-
1
1
<
5 % U
T
(>95 % dip in UT
)
for
0,
5 cycle
40
% UT
(60
% d
ip
in
UT
)
for 5
cycle
s
70
% UT
(30 % dip
in
UT
)
for 25
cycles
<
5
%
UT
(>95
%
dip
in
UT
)
for
5
s
e
c
<5%
UT
fo
r 5 s
(>95
% dip
)
complie
s by use
of
internal battery
A/C
pow
e
r qua
lit
y should be
that of a typical commercial or
hospital environment. If the
user of the Space
Syste
m
re
quires continued operation
during long time A/C pow
e
r
interruptions, it is
recommended that the Space
System or component be
pow
ered from an
uninterruptible pow
er supply or
a battery.
t
es
t
l
evel
I
E
C
6
0
6
0
1
-1
-2
I
E
C
6
0
6
0
1
-2
-2
4
C
o
mp
l
i
an
c
e
l
evel
E
l
ec
t
ro
mag
n
et
i
c
en
vi
ro
n
men
t
–
g
u
i
d
an
c
e