It is recommended that all pumps at
your care unit are equipped with the
same software version.
Perfusor® Space
and Accessories
Instructions for Use
GB
Valid for software 688M

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Braun Perfusor Space and is the answer not in the manual?

Braun Perfusor Space Specifications

General IconGeneral
Device TypeInfusion Pump
Accuracy±2%
Bolus RateAdjustable
Power Supply100-240 V AC, 50/60 Hz
DisplayLCD
AlarmsSystem error
Occlusion PressureAdjustable
Battery LifeApprox. 8 hours at 25 ml/h
CompatibilityB. Braun Space System
CertificationCE
Volume Preselection0.1 to 9, 999 ml

Summary

Perfusor Space Overview

Syringe Fixation

Instructions on how to correctly insert and secure a syringe.

Patient Safety

Intended Use and Patient Criteria

Defines the device's purpose, patient scope, and procedure suitability for TCI.

General Safety and Operational Guidelines

Covers safe operation, positioning, inspection, and device placement.

General Safety Instructions and Precautions

Detailed instructions for safe syringe handling, line management, and environmental conditions.

Specific Safety Measures

Safety guidelines for enteral nutrition, accessories, electrical connections, and PCA usage.

TCI and PCA Safety Instructions

Safety guidelines specific to TCI and PCA, including data lock and drug interactions.

TCI Monitoring and Pole Clamp Safety

Recommendations for TCI monitoring and safety instructions for using the Pole Clamp.

Menu Structure and Navigation

Operation

Start of Infusion Procedure

Step-by-step guide for powering on the pump and starting an infusion.

Syringe Insertion and Confirmation

Instructions for inserting, confirming, and handling the syringe and drive mechanism.

Parameter Entry Methods

Describes methods for entering rate, VTBI, and time combinations.

Bolus Application Methods

Details the three ways to administer a bolus dose.

Syringe Change and New Therapy Start

Procedure for changing a syringe and initiating a new therapy session.

Advanced Operations

Special Functions

Dosing Units and Dose Rate Calculation Overview

Explains dosing units, calculation formula, and BSA calculation.

Dose Rate Calculation Operation Steps

Step-by-step guide for operating the dose rate calculation feature.

Drug Library Functionality

Information on loading, assigning, and using drugs from the library.

Patient Controlled Analgesia (PCA) Setup

Steps for setting up and configuring PCA therapy.

Target Controlled Infusion (TCI) Overview

Introduction to TCI, PK models, and TCI modes.

TCI Setup and Patient Data Input

Guidance on setting up the pump for TCI and inputting patient data.

TCI Information Display and Finishing

Details on TCI screen display, information requests, and therapy finishing.

Ramp and Taper Mode Setup and Operation

Steps for starting and operating Ramp and Taper modes via drug library or menu.

Program Mode Setup and Operation

Steps for starting and operating Program Mode via drug library or menu.

Intermittent Mode Functionality

Description of the Intermittent Mode and its phases.

Intermittent Mode Setup and Operation

Steps for starting and operating Intermittent Mode via drug library or menu.

Dose Over Time Functionality

Explanation of the Dose Over Time therapy, its restrictions, and usage.

Autoprogramming

Options

Alarms

Battery Operation and Maintenance

Technical Data

Warranty, Service, Training, and Disposal