BREN-TRONICS, INC.
10 Brayton Court
Commack, NY 11725
P: 631-499-5155 | F: 631-499-5504
www.bren-tronics.com
Page 24 of 25
ALT 170C
(BTC-70844-2)
PR4G WORKSHOP CHARGER
OPERATION MANUAL
850084 REV D
Data presented in this document is subject to change without notice
ITEM MALFUNCTION POSSIBLE CORRECTIVE ACTION
10
Port LED goes to Amber (CHARGE),
but never turns Red (FAULT) or
Green (READY), instead it turns off.
1) Poor Connection, inspect and clean battery and
adapter contact.
2) Defective Adapter. Use a different adapter.
3) Defective Charger Port, try a different position.
4) Defective Battery, replace the battery.
11
Revitalize LED will not turn on when
button is pressed or turns off when
the battery is “Found”.
1) The Battery or Adapter does not support
Revitalizing or Destorage.
12
Revitalize LED is blinking and the
Port Status LEDs are all off.
1) The charger is too hot (over 40˚C) to discharge the
battery. Move the charger to a cooler area.
2) The air vents at the left and right side of the charger
are blocked.
3) Operating the chargers edge to edge can cause
overheating of the charger on the right.
4) The internal fan has failed. The unit requires repair.
Call or e-mail Bren-Tronics. Info on warranty tag.