2
IMPORTANT INFORMATION
FOR SERVICE PERSONNEL
Read all instructions and safeguards included in the original packaging and in this service manual carefully and completely before installing, operating or
servicing this appliance. Additional copies of installation instructions and service manuals are available upon request.
The proper performance of service is essential for the safe and effective operation of this appliance. Repairs should be performed by qualified service personnel
only. If you are unable to, or need help servicing this appliance, contact the nearest Brewmatic Authorized Service Agent or you can contact Brewmatic at 800-
421-6860.
Only Authorized Replacement Parts Should Be Used. Part substitutions could create a fire hazard and the risk of personal injury. The use of replacement parts
or accessory attachments not recommended by Brewmatic may be hazardous.
Do Not By-Pass Any Safety Mechanisms Or Operate This Appliance Without Covers In Place. Brewmatic requires that all safety devices and covers are in
place and functioning at all times to guard against a fire hazard and the risk of personal injury.
Brewmatic Does Not Recommend, And Will Not Furnish Anyone With Information For Changing The Electrical Rating Of Any Appliance Manufactured Or
Distributed By Brewmatic. Brewmatic will not approve of any unauthorized changes to the basic design of this appliance. Any modification or alteration to the
appliance may create a fire hazard, may create a risk of personal injury, may void the safety listings and may void the warranty.
Plumbing connections - All plumbing connections to water supply lines and drains should be performed by a licensed plumber complying with all applicable
plumbing codes having jurisdiction.
Electrical connections - With the exception of cords with plugs already attached, all electrical connections or alterations to the power supply should be
performed by a licensed electrician complying with all applicable electrical codes having jurisdiction.
When repairing or replacing internal electrical wiring, in part or in whole, use only terminals and wires with the same rating, gauge and insulation covering.
When calling for information, parts or service, have the model number, serial number, voltage, wattage, phase and date of purchase available. Electrical
information may be obtained from the electrical information nameplate located on the appliance.
All procedures, diagrams and specifications contained in this manual are based on the latest information available at the time of publication. Information, parts
and specifications are subject to change without notice.
We assume no liability for any damage to person or property caused by the utilization of this publication to effect maintenance or repairs.
Due to periodic reviews and changes in safety listing standards, listings and approvals may change at any time. For current listing and approval information
contact Brewmatic.
SPECIFICATIONS
Appliance Information
Model Number: 1030354, 1033058, 1033044 Model: 1033055, 1033059, 1033049
Description: Diplomat VI, 2 Station Pour-Over Coffee Brewer Description: Diplomat II, 3 Station Pour-Over Coffee Brewer
Volts: 120 Volts: 120
Watts: 1480 Watts: 1570
Amps: 12.3 Amps: 13.1
Hertz: 60 Hertz: 60
Phase: 1 Phase: 1
Power Supply Cord: 6 ft., 2 wire + ground. 15 amp, 14 awg.
Plug: NEMA 5-15P. Furnished and attached.
Power Supply Required: 120 volts, 15 amp, dedicated circuit.
Wall Receptacle Required: NEMA 5-15R. Not furnished.
Listings: UL 704J, NSF-4
Optional Accessories: 1030801, 3 Station top cover with warmer.
Additional Information
Brewing Capacity: 60 oz. maximum.
Brewing Temperature:
Approximately 188° to 192°F, maximum. Adjustable.
Temperature Adjustment: 3 Increase. 4 Decrease.
Hi-Limit Thermostat: Manual reset. Not adjustable.