Owner’s Manual
Manuel de l'utilisateur
Manual del Propietario
Model 01532-2
Manual No. 192115GS
Revision 0 (01/07/2003)
Questions? Help is just a moment away!
Vous avez des questions? Vous n'avez pas besoin d'aller loin pour trouver de l'aide!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline - 1-800-743-4115 M-F 8-5 CT
Appelez: Ligne d'assistance de Générateur - 1-800-743-4115 M-F 8-5 CT
Llamada: Generador Helpline - 1-800-743-4115 M-F 8-5 CT
1000
Starting
Watts
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WISCONSIN, U.S.A.

Questions and Answers

  • M
    Melissa WalkerAug 18, 2025
    Why won't my Briggs & Stratton 01532-2 start or runs rough?
    • W
      williamgarnerAug 18, 2025
      If your Briggs & Stratton Portable Generator engine won't start or runs rough, there are several potential causes: * Ensure the engine switch is set to 'On'. * Verify the fuel valve is in the 'Open' position. * Check and clean or replace the air cleaner if it's dirty. * Make sure the generator has gasoline; if not, fill the fuel tank. * If the gasoline is stale, drain the tank and carburetor, then refill with fresh fuel. * Confirm the spark plug wire is connected to the spark plug; if not, connect it. * Replace the spark plug if it's bad. * Drain the gas tank and carburetor and fill with fresh fuel if there's water in the gasoline. * If overchoked or flooded, wait 5 minutes and re-crank the engine.
  • J
    Joseph ClarkeAug 23, 2025
    What to do if my Briggs & Stratton 01532-2 engine shuts down when running?
    • A
      Amber GrahamAug 23, 2025
      If your Briggs & Stratton Portable Generator engine shuts down while running, the possible reasons are: 1. The generator is out of gasoline. Refill the fuel tank. 2. The oil level is low. Fill the crankcase to the proper level.
  • M
    mirandamortonAug 26, 2025
    Why does my Briggs & Stratton 01532-2 Portable Generator lack power?
    • T
      thomasweberAug 26, 2025
      If your Briggs & Stratton Portable Generator lacks power, it could be due to: * The load being too high. * A dirty air filter. Replace the air filter.
  • T
    Taylor GarciaAug 28, 2025
    How to troubleshoot no AC or DC output on my Briggs & Stratton 01532-2 Portable Generator?
    • S
      Stephanie DayAug 28, 2025
      If your Briggs & Stratton Portable Generator has no AC or DC output but the engine is running, consider the following: * Check if one of the circuit breakers is open and reset it. * Inspect for poor connections or defective cord sets and repair them. * Ensure the connected device is in good condition by connecting another device that is known to be working.
  • L
    Linda WrightAug 30, 2025
    What to do if my Briggs & Stratton 01532-2 Portable Generator bogs down when a load is connected?
    • D
      Devin DavisAug 30, 2025
      If your Briggs & Stratton Portable Generator runs well at no-load but bogs down when loads are connected, it could be due to: 1. A short circuit in a connected load. Disconnect the shorted electrical load.
  • R
    Richard JeffersonSep 2, 2025
    How to fix a Briggs & Stratton 01532-2 engine that 'hunts' or falters?
    • M
      Megan JohnsonSep 2, 2025
      If the engine of your Briggs & Stratton Portable Generator 'hunts' or falters, it might be because the choke is opened too soon. Try moving the choke to the halfway position until the engine runs smoothly.
  • J
    Jessica MichaelSep 5, 2025
    What to do if my Briggs & Stratton Portable Generator has no AC or DC output but the engine is running?
    • B
      Brittney TateSep 5, 2025
      If your Briggs & Stratton Portable Generator's engine is running but there's no AC or DC output, here's what you can check: * A circuit breaker might be open: Reset the circuit breaker. * There might be a poor connection or defective cord set: Check and repair the connection or cord set. * The connected device might be faulty: Connect another device that is in good condition.
  • A
    April PayneSep 7, 2025
    Why does my Briggs & Stratton Portable Generator engine shut down when running?
    • J
      Jodi MillerSep 7, 2025
      Your Briggs & Stratton Portable Generator's engine might shut down while running because it is out of gasoline, so fill the fuel tank. Another possible reason is low oil level, in that case fill the crankcase to the proper level.
  • S
    Stephen ConleySep 9, 2025
    What to do if Briggs & Stratton 01532-2 runs good at no-load but “bogs down" when loads are connected?
    • T
      tmillerSep 10, 2025
      If your Briggs & Stratton Portable Generator runs well without a load but bogs down when loads are connected, it could be due to a short circuit in a connected load. Disconnect the shorted electrical load. Also, the generator might be overloaded. Check “Don't Overload the Generator”.
  • T
    Terri TaylorSep 12, 2025
    Why Briggs & Stratton 01532-2 engine lacks power?
    • C
      caseyfordSep 12, 2025
      If your Briggs & Stratton Portable Generator engine lacks power, it might be because the load is too high. Check “Don't Overload the Generator”. Another possible reason is a dirty air filter, so replace the air filter.

Summary

Safety Rules: Key Hazards and Precautions

Carbon Monoxide, Electrical, and Battery Dangers

Details risks from carbon monoxide, grounding, batteries, and voltage.

Fuel Flammability and General Warnings

Covers fuel risks, USCG regulations, and operating precautions.

Safety Rules: Additional Hazards and Handling

Spark, Heat, Speed, and Overload Hazards

Addresses risks of sparks, hot surfaces, operating speeds, and overloading.

Assembly: Setup and Initial Procedures

Carton Contents and Oil Addition

Instructions for checking carton contents and adding engine oil.

Fueling the Generator

Safety and procedure for adding fuel to the generator tank.

Operation: Grounding and Starting

Generator Grounding Procedure

Explains how to properly ground the generator for electrical safety.

Engine Starting Sequence

Step-by-step instructions for starting the generator engine.

Operation: Loads, Stopping, and Oil Alert

Connecting Electrical Loads

Guidelines for connecting appliances, including overload warnings.

Stopping the Engine and Oil Alert System

Procedures for stopping the engine and understanding the oil alert system.

Battery Charging Safety Warnings

Critical safety precautions for charging batteries, including gas and acid hazards.

Dont Overload Your Generator: Capacity and Power Management

Calculating Generator Wattage Requirements

Steps to select items and calculate total running and surge watts needed.

Engine Maintenance: Oil Level and Oil Change

Spark Plug Cleaning and Replacement

Procedure for cleaning, inspecting, and gapping the spark plug.

Storage Instructions: Long Term Preparation

Fuel System Protection for Storage

How to protect the fuel system from gumming and moisture during storage.

Troubleshooting Common Generator Issues

No Output or Bogging Down Problems

Solutions for generator having no output or shutting down under load.

Starting and Running Rough Issues

Troubleshooting steps for engine not starting or running rough.

Engine Shutdown and Power Loss

Addresses issues like engine shutting down or lacking power.

Emission Control System Warranty

Owners Warranty Rights and Obligations

Explains the owner's responsibilities and BSPP's warranty coverage for emission control parts.

Emission Control Warranty Provisions

Details specific provisions like warranted parts, length of coverage, and exclusions.

Briggs & Stratton Owner Warranty Policy

Briggs & Stratton 01532-2 Specifications

General IconGeneral
Model01532-2
TypePortable Generator
Starting SystemRecoil
Fuel TypeGasoline
Fuel Tank Capacity1.1 gallons
Run Time at 50% Load8 hours
Weight53 lbs
Engine BrandBriggs & Stratton
Run Time8 hours at 50% load
Noise Level68 dBA
WheelsNo
Engine Type4-cycle OHV
Outlets1 x 120V 20A
Engine4-cycle OHV
Power Output1.5 kW
Outlet Types120V 20A

Related product manuals