4.2 Electrical!Installation!
4.2.1 Electrolysis!Cell!!
The!electrolysis!cell!needs!two!4!to!10!mm
2
!electrical!wires!(depending!on!cell!powe r)!and!two!0,75!mm
2
!
wires,!bot h !provided!with!the!equipmen t .!The!wires! are!crimped!w ith!ring!ton gue!terminals!and !should!
be!connected!as!shown!in!Fig!5.!!
!
!
!
Fig!5!–!Electrolysis!Cell!Connection!T e r minals!
!
4.2.2 Temperature!Sensor!
The!temperature!probe!m ust!be!connected!to!the!equipment!on!terminals!of!the!power!board!(check!
connections!diagram!supplied!with!the!equipment).!
4.2.3 External!Controller!(optional)!
If!you!choose ! t o ! install!an!external!contro lle r,! y o u ! s ho u ld !connec t! a ! fre e!potential!signal!to!the!terminals!
of!ELECTRAL!power!board!(check!connections!diagram!supplied!with!the!equipment ).!
4.2.4 Cover!Detector!(optional)!
If! the ! pool! has! an! electrical! cover! system,! you! can! connect! it! to! the! ELECTRAL! model,! in! order! to!
automatically!detect!when!the!cover!is!closed!and!immediately!reduce!sanitation.!!
The!connection!is!done!through!a!free!potential!signal!on!the!terminals!of!ELECTRAL!power!board!(check!
connections!diagram!supplied!with!the!equipment).!!
!
Attention:! the! cove r! button! is! a ls o ! co n n e cte d ! to! th is! terminal! (for! non-electrical! covers)! you! can!
maintain!both!connections!or!inhibit!the!button !by!remo vin g!the !respe ctive!co nn ectio n .!!
!
5 Operation!
!
!
The!control!mode!of!chlorine!sets!the!electrolysis!process.!The!adequate!setup!w ill!depend!of!the!pool!
where!the!system!is!installed.!!
!
This! m ode!of!operation!will!only!work!when! the!circulation!pump!is!connected,! by!manually!choosing!a!
period!for!electrolysis!(as!a!percentage!of!the!filtration!time),!or!autom atically!according!to!the!water!
temperature.!
Always!start!the!circulation!pump!before!turning !on!th e! co ntroller.!