The!information!in!this!document!is!subject!to!change!without!notice! 29!
!
!
why!the! use!of! salt!is!insignificant).!If! the! disinfection!takes!place!over!night,!the!chlorine!con centration!
increases!ra p id ly!a n d !th e !d isin fe c ta nt !eff ec t!is!more!effectiv e.!
!
It!is!also !advisable!to !maintain!th e !concentratio n !of! is o c ya n u ric !acid!(chlorin e!stabilizer)!aro u n d !35ppm,!
ie! 35 ! g/cbm ! of! water.! T h is! concen tratio n ,! although! minimal,! allow s! minimizing! the! d i u rn a l! losses! of!
chlorine!through!the!effec t!of!ultravio let!radiatio n. !
!
5.6 Low!Temperature!Operation!
!
!
Failure!to!comply!with!this!procedure!will!invalidate!any!warranty!of!the!equipment!and!the!cell.!
!
5.7 Operation!with!Pool!Coverage!
The!production!of!chlorine!when!the!po ol!is!covered!should!be!lower!than!w hen!it!is!uncovered.!If!the!
cover!has!an!electrical!control! unit,!it!is!po ssible!to! autom ate!the!p rocess!(see !section!4.2.4).!If ! th e !cover!
is!manua l,!the !side!sw itch!sh ou ld!be!in! position!“II”!whenever!the!covered.!
!
The!cover!detector!reduces!the!electro lysis!perio d!for!10 % !of!the!filtering !time . !
!
6 Alarms!
6.1 Alarm!1!–!Low!Flow!
This! alarm! (A LA RM! 1)! is! triggered ! when! the! water! flow! e n te rin g! the! electrolysis! cell!is! too! low.! The!
system!will!automatically!switch!to!standby!mode!to!safeguard!its!in te g rity .!
! Check!if:!
all!valves!a re !in!t h e!c o rre ct!p o s itio n!
there!is!water!leakage!in!hydraulics!
the!filter!is!in!the!filtering!position!
the!electrical!switches!are!all!connected!
!
The!alarm!deactivates!automatically!once!the!problem!is!solved.!!
!!
6.2 Alarme!2A!–!Hight!Salt!
This!alarm!(ALARM !2A)!is!released!when!the!electrolysis!reaches!the!maximum!threshold!of!130%.!This!
indicates!that!the!salt!c o n c en tra tio n !in!the!pool!is !above!the!maximu m!desirable!to!p re se rve !the!cell.!
The! amount! of! salt! shou ld! be! inferred!by! the! w ate r! volum e! of! the! pool! and! reduced! accordingly.! In!
alternative,!the!current!can!be!adjusted!to!the!new!salt!concentration!(see!5.5.1).!!
Check!if:!
salt!concentration!is!between!0,5!and!1,5!g/l!
the!salt!is!completely!diluted!in!water!
all!valves!are!in!the!correct!position!
the!power!supply !is!well!re gu lated !
the!equipment!is!corre ctly!c alibrated!
!
Once!the!problem!is!corrected,!reboot!the!equipment!to!deactivate!the!alarm.!
!
When! the!water! temperature!is!less!than!12ºC,!electrolysis!production!must!be!turned!off!to !avoid!
cell!damage.!The!models!with!temperature!probe!included!(ELECTRAL)!this!process!is!automatic.!