BRIGHT BLUE ELECTRAL - Alarm 3 - Low Temperature; Alarm 4 - Aged Cell; Maintenance and Warranty; Electrolysis Counter

BRIGHT BLUE ELECTRAL
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
!
©Copyright!! !EN-V2016!
The!information!in!this!document!is!subject!to!change!without!notice! 30!
!
!
6.3 Alarme!2B!–!Low!Salt!
This!alarm!(ALARM!2B)!is!released!when!the!electrolysis! reach es! the! minimum!threshold!of!66%.!The!
system!continues!to! o perate,!but! the!production!of!electrolysis!is!reduced!and!m ay!be! insu fficient!for!a!
good!disinfection!of!the!water.!This!alarm !indicates!that!the !salt!co nce ntra tion!in!the!pool!is!b elo w!the!
minimum!desirable,!or!that!there!is!an! anomaly! in! th e! electrolysis!cell.! The! am ount! of!salt!should!be!
inferred!by!the!water !vo lume!of!the!pool!and!increased!accordingly.!!
Check!if:!
salt!concentration!is!between!0,5!and!1,5!g/l!
the!salt!is!completely!diluted!in!water!
all!valves!are!in!the!correct!position!
the!power!supply !is!well!re gu lated !
the!equipment!is!corre ctly!c alibrated!
the!cell!plates!have!minera l*!de pos i ts,!e.g.!“wh ite!electro de s” !
!
(*)!–! In!this! case! intr o d u ce ! the! elec tro d e s ! in!a! s o lu tio n ! of!10% ! hydrochlo ric ! acid! until!the! "bubbling"!
disappears,! ty p ic a lly !after!1 0 !minutes .!Manual! cleaning!reduce s!the!lifetime!of!the!cell!so!it!should!only!
be!made!if!the!deposition!is!well!visible.!!
!
The!alarm!deactivates!automatically!once!the!problem!is!solved.!!
6.4 Alarm!3!–!Low!Temperature!
This!alarm!(ALARM !3)!is! trig ge red !when !the!w ater!temperatures!is!less! than ! 5 ºC !as!a!warning!of! possible!
water!pipe!freezing.!In!this!case,!it!is!advisable! to!program!a!10!m inutes! circulation! period! every! h our! to!
prevent! water! from! freezing! within! the! tubing.! Once! the! temperature! rises! the! alarm! turns! off!
automatically.!
!
If!the!water!tem pe ratu re!is!not!less!tha n!5° C!service!should!be!consulted.!!
!
6.5 Alarm!4!–!Aged!Cell!!
This!alarm!(ALARM!4)! is!released!if!the!electrolysis!cell!is!producing!below!30% !of!its !nominal! value!("S:!
29%"!or!less).!This!indicates! that! the!cell!is! near!the!end!of! its! useful! life! and!should! be!replaced!shortly,!
or!the!salinity!of!the!water!is!too !low.!The!productio n !of!chlorine!is!reduced!and!the!filtration!time!will!
be!significantly!increased!for!the!system!to!achieve!the!level!of!chlorine!required!for!disinfecting.!
Check!if:!!
salt!concentration!is!between!0,5!and!1,5!g/L!
the!salt!is!completely!diluted!in!water!
all!valves!are!in!the!correct!position!
the!power!supply !is!well!re gu lated !
the!equipment!is!corre ctly!c alibrated!
the!cell!plates!have!minera l*!de pos its,!e.g.!“wh ite!electro des !
!
The!alarm!deactivates!automatically!once!the!problem!is!solved.!!
!
7 Electrolysis!Counter!
This!model!is!equipped! with! an! electrolysis!counter,!that!is,!a!clock! that! monitors!the!use! and! lifetime!of!
the!electrolysis!cell.!The!device!counts!the!hours!the!cell!is!actually!operating,!discarding!the!hours!the!
system!is!on!but!n ot!producing!chlorine.!To!see!the!total!time!o f!electrolysis!press!the!button!for!5!sec!
until!the!information!appears!on!the!screen.!
!