  • J
    Joseph ThomasSep 23, 2025
    What to do if there is a defect to the sensor for cooling capacitor in Brilix Swimming Pool Heater?
    • L
      Laura BondSep 23, 2025
      If there is a defect to the sensor for cooling capacitor in your Brilix Swimming Pool Heater, the sensor is either open or short-circuited. Check or replace the sensor.
  • K
    Kristina HartAug 23, 2025
    Why is my Brilix XHP 140 Swimming Pool Heater showing protection against low pressure?
    • S
      Samantha GarciaAug 23, 2025
      If your Brilix Swimming Pool Heater shows a protection against low pressure error, it could be due to several reasons: a lack of coolant, insufficient flow, or a clogged filter or capillary tubes. To resolve this, check the gas for leakage and add coolant if necessary. Also, clean the air exchanger. Finally, change the filter or replace the capillary tubes.
  • C
    Christopher KeyAug 25, 2025
    Why is my Brilix Swimming Pool Heater showing protection against high pressure?
    • B
      Brenda MartinezAug 26, 2025
      If your Brilix Swimming Pool Heater indicates protection against high pressure, it may be due to too much coolant or insufficient air flow. To fix this, remove the excess coolant from the heat pump system and clean the air exchanger.
  • J
    Jennifer SmithAug 27, 2025
    What to do if there is too much ice on the evaporator of my Brilix XHP 140?
    • K
      Kara WellsAug 27, 2025
      If there is too much ice on the evaporator of your Brilix Swimming Pool Heater, it may be caused by insufficient air ventilation or a lack of coolant. Check the location of the heat pump unit and remove any obstructions preventing good air ventilation. If that doesn't resolve the issue, consider replacing or repairing the heat pump unit.
  • S
    Suzanne WalshAug 27, 2025
    What to do if my Brilix XHP 140 Swimming Pool Heater has a short run?
    • J
      Jeremy BoyleAug 28, 2025
      If your Brilix Swimming Pool Heater experiences a short run, it could be due to the fan not running, insufficient air ventilation, or a lack of coolant. Check the cable connections between the motor and the fan, and replace them if necessary. Also, check the location of the heat pump unit and remove any obstruction preventing good air ventilation. If the problem persists, replace or repair the heat pump unit.
  • K
    Katherine SanfordSep 18, 2025
    What to do if there is a defect to the temperature sensor for incoming water in Brilix XHP 140?
    • J
      Jessica IbarraSep 18, 2025
      If there is a defect to the temperature sensor for incoming water in your Brilix Swimming Pool Heater, the sensor is either open or short-circuited. Check or replace the sensor.
  • H
    Heather FloresSep 15, 2025
    What to do if there is a defect to the sensor for capacitor heating in Brilix XHP 140?
    • T
      torreslauraSep 15, 2025
      If there is a defect to the sensor for capacitor heating in your Brilix Swimming Pool Heater, the sensor is either open or short-circuited. Check or replace the sensor.
  • A
    Aaron BallSep 16, 2025
    What to do if there is a defect to the temperature sensor for outgoing water in Brilix XHP 140 Swimming Pool Heater?
    • J
      Jessica KelleySep 17, 2025
      If there is a defect to the temperature sensor for outgoing water in your Brilix Swimming Pool Heater, the sensor is either open or short-circuited. Check or replace the sensor.
  • E
    Erin DeanSep 6, 2025
    What to do if the outgoing cooling water temperature is too low in my Brilix Swimming Pool Heater?
    • M
      Mr. Joshua MoralesSep 7, 2025
      If the temperature of outgoing cooling water is too low in your Brilix Swimming Pool Heater, it is probably caused by insufficient water flow. Check the volume of water flow and whether or not the water passes through.
  • C
    Cheryl AllenSep 4, 2025
    What happens during the first stage of the frost protection system of Brilix Swimming Pool Heater?
    • A
      Austin VelezSep 4, 2025
      During the first stage of the frost protection system of your Brilix Swimming Pool Heater, the pump will run automatically if the ambient temperature or the temperature of incoming water is too low.

Summary

Specification

1.1 Horizontal EU design, R410 A,HEATING AND COOLING

Technical specifications for the horizontal EU design R410A heat pump models.

Performance curves

Heat Output Curves

Graphical representation of heat output versus air temperature for various models.

Input Curves

Graphical representation of input power versus air temperature for various models.

COP Curves

Graphical representation of COP versus air temperature for various models.

Dimensions

Installation

4.1 Installation illustration

Diagram illustrating the physical installation layout of the heat pump system.

4.2 Selection of the installation position

Guidelines for choosing the optimal location to install the heat pump for best performance.

4.3 Chemical elements position and service life

Importance of chemical element placement for the heater's service life.

Electrical connection

5.1 Connection diagram for the swimming pool heat pump XHP 40, XHP 60, XHP 100

Wiring diagram for connecting the heat pump models XHP 40, 60, and 100.

5.2 Connection diagram for the swimming pool heat pump XHP 140

Wiring diagram for connecting the heat pump model XHP 140.

5.3 Connection diagram for the swimming pool heat pump XHP 200

Wiring diagram for connecting the heat pump model XHP 200.

Initial heat pump start-up and its winterization

THE START-UP PROCEDURE

Step-by-step instructions for the initial operation and setup of the heat pump.

6.1 Heat pump winterization

Essential measures for preparing the heat pump for the winter season.

6.2 Starting up the heat pump again after winter

Procedure for safely recommissioning the heat pump after winter storage.

Setting operating data

7.2 Control display functions

Overview of the buttons and display elements for controlling the heat pump.

7.3 How to identify the operating parameters

Guide to understanding and checking the heat pump's operational parameters.

7.4 How to identify the current mode?

Method for determining the current operating mode of the heat pump.

7.5 Setting the water temperature

Instructions for adjusting the desired water temperature for heating or cooling.

7.8 Setting the activation of the timer

Procedure for programming the timer to switch the heat pump on.

Troubleshooting

8.1 Error codes shown on the controller with LED display

Explanation of error codes displayed on the controller and their solutions.

8.2 Other faults and solutions (with no display on the controller with LED)

Troubleshooting guide for faults without error codes on the LED display.

Schematic representation and list of parts

Spare parts 1

Spare parts 2

Cabling diagram (example - XHP 60)

Replacement of parts

Warranty terms and conditions

Safe disposal of the product after its service life

Claims and servicing