Model XHPFD 160 E XHPFD 210 E XHPFD 260 E
* Performance at Air 27°C, Water 27°C, Humidity 80%
Heating (Max./Std./Min.) kW 17-3,8 - -
Power consumption (Std.) kW 2,54-0,29 - -
C.O.P. (Std.) 13-6,7 - -
* Performance at Air 15°C, Water 26°C, Humidity 70%
Heating (Max./Std./Min.) kW 11,5-3 - -
Power consumption (Std.) kW 2,2-0,37 - -
C.O.P. (Std.) 8.2-5.2 - -
When water flows m
3
/h 5.00
Voltage 220 ~ 240 V/50 Hz/1 PH
Std. Current Input A 7,2 9 11,9
Maximum Current A 11,31 25 32
Minimum fuse A 31
Water in-out connection mm 50
Fan quantity 1 2
Ventilation type Horizontální
Compressor brand MITSUBISHI MITSUBISHI PANASONIC
Compressor type stejnosměrný, se střídačem, rotační
Noise level at 1m dB(A) 41-56 41-56 41-56
Coolant (R410a) kg 1,7 1,7 1,7
GWP 2088 2088 2088
CO2 Ekvivalent - tun 3,55
Net dimension mm 1070 x 410 x 850
Net weight kg 95 - 130
Packing dimension mm 1140 x 430 x 990 1150 x 450 x 1360
Gross weight
kg
110 - 142
* Above data may be modified without notice.
* Obsahuje fluorované skleníkové plyny