5.4 Schéma zapojení bazénového tepelného čerpadla
XHP 200 Tri ,XHPFD200 Tri
* The dotted line part are only used in some models
BLU
BLU
2
Transformer
5
Electronic Expansion Valve
Current
checking
L1
Current
checking
RUN
K1
1 3
42
ON
R
S
T
N
A
B
C
N
1
2
2
2
2
POW
RED
ORG
U/T1
RED
YLW/GRN
BLK
WHT
AC CONTACTOR
RED
BLK
WHT
RED
BLK
WHT
RED
RED
RED
BRN
L4
BLK
WHT
W/T3
V/T2
YLW/GRN
YLW/GRN
YLW/GRN
LED
OUT2
OUT1
OUT3
OUT4
OUT5
AC- N
CN1
CN2
4-WAY VALVE
3
Low voltage switch
Remote controller
High voltage switch
Phase sequence protection
CN3
SW1
BRN
BLU
YLW
12V
ENT
GND
GND
GND
GND
GND
GND
KYIN
FS
LP
HP
PP
2
2
2
2
2
2
Water out temperature
Water inlet coil temperature sensor
H coil temperature eating
Ambient emperature t
back temperature
CN4
GND
GND
GND
GND
GND
GND
T6
T5
T4
T3
T2
T1
COMPRESSOR
Programming
PC Board
FAN CAPACITOR
3
4
3
4
FAN MOTOR
Crankcase heater
Crankcase
heater
BRN
BRN
BRN
BRN
temperature
controller
380-415V 3N 50Hz
~
Flow switch failure
cooling pipetemperature sensor
N
SWITCH
BLU
3-XPDLT0052
13
12
* The dotted line part are only used in some models
RUN/POW
2
2
2
2
2
3
Low Pressure switch
Water flow switch
5
Electronic Expansion Valve
Controller
High Pressure switch
Water out temperature
Water in temperature
Heating pipe temperature
Ambient temperature
Back temperature
Phase sequence protection
2
Transformer
2
FAN MOTOR
RED
ORG
C1
YLW/GRN
BLK
COMPRESSOR
YLW/GRN
S BLK
C2
R WHT
WHT
4-WAY
BLU
BRN
OUT1
OUT2
3
3
4
4
OUT3
OUT4
OUT5
AC-N
CN1
SW1
CN5
CN4
CN2
BRN
BLU
RED
BLU
C RED
BLU
RED
AC CONTACTOR
BRN
BLU
Remote controller
Base Electric Heater
YLW/GRN
220-240V ~ 50Hz
BLU
BRN
3-XPDLT0022S
PE
L
N
SWITCH
BRN
RED
(Water Pump)
Model: XHPFDPLUS160XHPFDPLUS140 &
Note: Electrical connection
The power supply for the heat pump must come, preferably, from an exclusive circuit with regulatory
protection components (30mA differential protection) and a magneto-thermal switch.
- The electrical installation must be carried out by a specialized professional (electrician) in accordance
with the standards and regulations in force in the country of installation.
- The heat pump circuit must be connected to a safety earth circuit at the terminal block.
13
5.Operation
5.1 The functions of LED wire controller
5.2 How to know operation parameter
(LED display show real time till HP unit is power off)
(1) Long press
5 seconds to enter operating parameter interface.
(2) Under parameter interface, Press
or
to check the parameters
(3) Leave it 8 seconds, LED will display water in temperature (under running) or time (until stops)
(4) Under current mode, press
or
to modify the water setting temperature whenever it is ON/OFF
status.
(5) While running, the LED displays the water-in temperature and current mode
LED display
Operation mode display
ON/OFF
Time button
Timer off button
Timer on button
Up and down button
- The cables must be properly installed to prevent interference.
- The pump is intended for connection to a general power supply with earth connection.
- Section of the cable; This section is indicative and should be checked and adapted according to the needs
and conditions of use.
- The tolerance of acceptable voltage variation is +/- 10% during operation.
The connections must be dimensioned according to the power of the device and the state of installation.
14