9.1 Wiring the Manual or Programmable Thermostat (HEATING ONLY)
Brivis Manual and Brivis Programmable Thermostats can be wired directly to a Classic heater for heating
only applications.
To connect the Thermostat to the unit:
Run twin core cable no less than 0.75mm² in cross section from the heater W & R Terminal Blockto
the thermostat location.
Remove thermostat backing plate from the front cover and mount on the wall.
Draw wires from the wall cavity, connect W & R terminals on the heater W & R Terminal Blockto the
W & R terminals on the thermostat, refer to Diagram 10 and Diagram 11.
Insert batteries and mount thermostat front cover onto the backing plate.
For more information refer to the Installation Guide and Operating Manual supplied with the Brivis
Manual or Programmable Thermostats.
Diagram 10. BX3 Thermostat Connection
Diagram 11. 2PWN, DF3 & UF3 Thermostat Connection
Note:
Only use Brivis Thermostats, as any failure relating to a non-Brivis Thermostat will not be covered
under warranty.
Note:
On the terminal block C, Y, G, TW1 & TW2 are not active.
Grommet
W & R Terminal
block
T/STAT
W
R
Field Supplied
Twin-core, figure 8
0.75mm² cable
T/STAT
W
R
Field Supplied
Twin-core, figure 8
0.75mm² cable
W & R Terminal
block
Note:
W&R terminal block for DF3 & UF3 can be found
beneath the control panel.
2PWN Illustrated.