1. Operate the multimeter switch to SIGNAL LEVEL (ATT).
2. Depress and hold the SQUELCH LEVEL ' section of the control for approximately 10 seconds. This
will lower the squelch point to the lowest level.
3. Lower the input signal level to the desired squelch point as viewed on the multimeter.
4. Depress the SQUELCH LEVEL , section of the control until the UNSQUELCHED indicator extinguishes.