Page 1
LOSONE SELECT
®
L100 SERIES • L150 SERIES
L200 SERIES • L250 SERIES • L300 SERIES
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
This manual is divided into sections as follows:
“WARRANTY”
“TYPICAL INSTALLATION”
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)
“MOUNTING OPTIONS”
“WIRING OPTIONS”
-Wiring Plate Position
“DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (vertical blower discharge)
“USE AND CARE”
“SERVICE PARTS”
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
WARRANTY
LOSONE SELECT
®
VENTILATORS
Ceiling/Wall Mount
BROAN-NUTONE CANADA ONE YEAR LIMITED WARRANTY
Broan-NuTone Canada warrants to the original consumer purchaser of its products
that such products will be free from defects in materials and workmanship for
a period of one year from the date of original purchase. THERE ARE NO
OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone Canada will, at its option, repair
or replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS
AND TUBES. This warranty does not cover (a) normal maintenance and service
or (b) any products or parts which have been subject to misuse, negligence,
accident, improper maintenance or repair (other than by Broan-NuTone Canada),
faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as
specified for the express warranty.
BROAN- NUTONE CANADA’S OBLIGATION TO REPAIR OR REPLACE, AT
BROAN-NUTONE CANADA’S OPTION, SHALL BE THE PURCHASER'S SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE
CANADA SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR
SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some jurisdictions do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary by jurisdiction. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone Canada at
the address or telephone number below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the
original purchase date.
Broan-NuTone Canada Inc.
1140 Tristar Drive, Mississauga, Ontario L5T 1H9 (1-888-882-7626)
99042810

Other manuals for Broan L100 Series

Question and Answer IconNeed help?

Do you have a question about the Broan L100 Series and is the answer not in the manual?

Summary

Safety Warnings

Intended Use

Operate the unit only as specified by the manufacturer.

Electrical Safety Precautions

Turn off power at the service panel and lock it before servicing or cleaning.

Installation Standards

Installation and wiring must be done by a qualified person per applicable codes.

Combustion Air Requirements

Ensure sufficient air for fuel-burning equipment to prevent backdrafting.

Utility Protection

Do not damage electrical wiring or hidden utilities when cutting or drilling.

Ducting Requirements

Ducted fans must always be vented to the outdoors.

Duct Material

Use only metal ductwork to reduce the risk of fire.

GFCI Protection for Tub;Shower

Unit over tub/shower must be GFCI protected.

Switch Location

Never place a switch where it can be reached from a tub or shower.

Grounding Requirement

This unit must be properly grounded.

Cautionary Notes

Intended Use (Caution)

For general ventilating use only, not for hazardous materials.

Motor and Impeller Care

Keep dust and debris off the power unit to prevent bearing damage.

Product Specifications

Refer to the specification label for further information and requirements.

Warranty Information

One Year Limited Warranty

Covers defects in materials and workmanship for one year from purchase.

Warranty Exclusions

Excludes normal maintenance, misuse, accident, improper repair, or faulty installation.

Remedy and Liability

Repair or replacement is the sole remedy; no liability for incidental damages.

Obtaining Warranty Service

Contact Broan-NuTone Canada with model, part info, defect description, and proof of purchase.

Typical Installation

Mounting (New Construction)

Instructions for mounting in new frame construction, showing bracket position and joist alignment.

Mounting (Existing Construction)

Instructions for mounting in existing frame construction, showing bracket orientation.

Wiring Connections

Diagram showing electrical connections to the wiring plate.

Ducting (Horizontal Discharge)

Methods for connecting ductwork to the unit in a horizontal discharge configuration.

Important Ducting Notes

Remove shipping tape from damper and shipping ring from blower inlet.

Mounting Options

Bracket Adjustment

Adjust mounting brackets using hex nuts for desired position.

Mounting Bracket Configurations

Various positions for mounting brackets relative to joists and housing.

Ducting Options

Blower Discharge Positions

Shows blower and duct connector in horizontal and vertical discharge positions.

Ducting (Vertical Discharge)

Typical ductwork connection for vertical discharge.

Wiring Plate Options

Wiring Plate Position

Illustrates wiring plate mounting to the side or top of the housing.

Use and Care

Continuous Operation

Unit designed for continuous operation, controllable via switch or speed control.

Cleaning Instructions

How to clean the grille and blower assembly, emphasizing motor protection.

Service Parts

Parts List

Detailed list of replacement parts with key numbers, part numbers, and descriptions.

Service Parts Diagram

Exploded view diagram showing the location of various service parts.

Ordering Replacement Parts

Instructions to order replacement parts by PART NO., not KEY NO.

Broan L100 Series Specifications

General IconGeneral
BrandBroan
ModelL100 Series
CategoryFan
LanguageEnglish