9 / 15
BROSA Force Measuring Pin
...............................................................................................................................................................
................................
................................
................................
................................
...............................
............................................................................................................................................................
................................
................................
................................
................................
............................
3 Advice on the safe handling of BROSA force measuring
pins
WARNING! Non-compliance with the following instructions can lead to sensor damage
and/or impairment of measurement results. The analysis of an erroneous measurement can
result in personal injury or material damage.
WARNING! Despite their sturdy design, BROSA force measuring pins may not be used
for any other than the intended purpose (see. Section 1.1). With improper use, dangers to life
and limb of the user or third parties and/or impairment of the device in which the force
measuring pin is implemented or other material assets can be caused.
3.1 Handling
WARNING! BROSA sensors contain high-quality measurement electronics. Make sure
they are handled carefully.
- BROSA force measuring pins are delivered in transport-safe packaging. We
recommended that you remove the sensors from the package immediately prior to
installation.
- The mass of the force measuring pin is to be observed when selecting appropriate
handling equipment and/or lifting gear; it is indicated on the nameplate.
- BROSA force measuring pins must be secured against falling. Do not throw sensors!
- Use as a tool (e.g., impact, slotting or lever tool) is not permitted; it can cause
damage to the sensor and thus falsify the measurement results.