- 5 -
Needle down centering
Standard
•
When the needle position dial is set to “M” and the zigzag dial is set to “0”, the needle should be in the
center of the needle plate hole.
Adjustment
•
Set the needle position selector to M and the stitch width knob to 0 .
•
Loosen the setscrew of the zigzag connecting rod .
•
Loosen the fixation screw of the eccentric nut .
•
Turn the eccentric nut to make adjustment.
•
Retighten the fixation screw of the eccentric nut .
• Retighten the setscrew .