ELECTRONIC CONTROLLERS
FOR INDUSTRIAL VIBRATORS
User's and maintenance
manual”
ENGLISH Manual not in original language VER. 4_0
BROVIND VIBRATORI SPA
Via Valle Bormida 5
12074 Cortemilia (CN)
ITALY
Tel. +39 0173 820111
Fax +39 0173 81853
E-Mail: brovind@brovindvibratori.it

Table of Contents

Questions and Answers

  • G
    George ClarkeAug 6, 2025
    How to fix BROVIND CFV when the display doesn't light up?
    • W
      williamslynnAug 6, 2025
      First, check that the power cable is properly connected to the mains. Next, open the controller box and ensure the power is correctly connected inside. Also, inspect the fuses on the board to see if they are in good condition. Finally, use a testing device to verify that power is reaching the switch on the controller box.
  • C
    Caroline WhiteAug 10, 2025
    What to do if BROVIND CFV Controller shows a short-circuit at output?
    • T
      Thomas FrankAug 10, 2025
      Turn off the controller immediately and inspect the output for any short-circuits. If no shorts are found, attempt to turn the controller back on. Additionally, check if the vibrator speed was accidentally set to 0 for safety reasons (A0) and reset it.
  • S
    Steve WardAug 14, 2025
    Why is the vibrator not working on my BROVIND CFV Controller?
    • M
      Mrs. Kathleen PetersonAug 14, 2025
      Make sure that all parameters are set correctly, including vibration amplitude, frequency, and the activation/deactivation of sensors. Also, verify that the vibrator is properly connected to the power board.
  • J
    jshafferAug 18, 2025
    What does Supply voltage alarm mean on BROVIND CFV?
    • K
      Kenneth LarsonAug 18, 2025
      The supply voltage alarm activates if the supply voltage falls below 50 Volts or exceeds 300 Volts.
  • G
    Gregory MitchellAug 23, 2025
    What to do if BROVIND CFV is stopped by a sensor?
    • D
      David GibsonAug 23, 2025
      Go to the menu for sensor 1 and/or sensor 2 and disable the sensor that is causing the issue.
  • M
    Michael HartmanAug 27, 2025
    How to reset BROVIND CFV Controller parameters to factory settings?
    • C
      christine21Aug 27, 2025
      The factory-set parameters can be restored by selecting configuration 5 in the “Saving Work Configurations” menu (Menu 40).
  • S
    Sean DanielAug 31, 2025
    What does SRV02 probe alarm mean on BROVIND CFV?
    • C
      carlbaileyAug 31, 2025
      This alarm indicates that the probe is set but is not responding. It activates if, with A0 greater than 1.0, As stays at 0 for at least 20 seconds.

Summary

CE DECLARATION OF CONFORMITY

PERSONAL SAFETY RULES

TECHNICAL DATA

CONNECTION DIAGRAM FOR CFF AND CFV CONTROLLERS

CONNECTION DIAGRAM FOR DCFF CONTROLLER

CONNECTION DIAGRAMS FOR SPECIFIC CFF MODELS

REMOTE POTENTIOMETER CONTROL

EXTERNAL 0-24 V COMMAND FOR ON;OFF CONTROL

SPECIAL APPLICATION: BALANCE FUNCTION

SPECIAL APPLICATION: ELEVATOR UNIT FUNCTION (DCFF ONLY)

SPECIAL APPLICATIONS: DISCHARGE UNIT AND ALARM RELAY

PROGRAMMING BOOLEAN LOGIC FUNCTIONS

SETTING INSTRUCTIONS AND MENU NAVIGATION

MENU 2: CHANGING VIBRATION AMPLITUDE

MENU 3: CHANGING FREQUENCY

MENU 4: CALIBRATED TRACKING

MENU 6: ASSIGNING SENSOR PX1

MENU 7: ASSIGNING SENSOR PX2

MENU 8: EXTERNAL COMMAND 0-10 V; 4-20 mA

MENU 11: PRE-SET ACCELERATION VALUES

MENU 14: AUTOMATIC CALIBRATION OF VIBRATOR

MENU 14: CALIBRATION SETTING PROCEDURE (CFV)

MENU 15: OUTPUT RELAYS FUNCTIONS

MENU 16: MAXIMUM CURRENT VALUE

MENU 17: SIMULTANEOUS STOP AND SYNCHRONIZATION (DCFF)

MENU 18: A-MAX SETTING WITHOUT SRV02 PROBE

MENU 19: SOFT-START AND SOFT-STOP RAMP

MENU 20 & 21: DEFAULT PARAMETER SETTINGS

MENU 26: PIECES-COUNTER FUNCTION - DISPLAY

MENU 27: PIECES-COUNTER FUNCTION - SETTINGS

MENU 28: TIME-OUT FUNCTIONALITY

MENU 30 & 31: RESET AND PARAMETER RESTORATION

MENU 37: Vi SETTING FOR CALIBRATION

MENU 40 & 41: WORK CONFIGURATION MANAGEMENT

MENU 45: PROGRAMMING LOGIC FUNCTIONS (BLOCKS)

MENU 46: LOGIC FUNCTIONS ENABLING AND ANTIBLOCK

MENU 50: COMMUNICATION AND BOARD ADDRESS SETTINGS

MENU 70 & 71: PASSWORD PROTECTION FOR PARAMETERS

MENU 81: OPEN \ CLOSED LOOP OPERATION

SRV02 PROBE DESCRIPTION

NETWORK MANAGEMENT AND MAINTENANCE

TROUBLESHOOTING GUIDE

TROUBLESHOOTING: DISPLAY MESSAGES