ELECTRONIC CONTROLLERS
FOR INDUSTRIAL VIBRATORS
User's and maintenance
manual”
ENGLISH Manual not in original language VER. 4_0
BROVIND VIBRATORI SPA
Via Valle Bormida 5
12074 Cortemilia (CN)
ITALY
Tel. +39 0173 820111
Fax +39 0173 81853
E-Mail: brovind@brovindvibratori.it

Table of Contents

Questions and Answers

  • R
    Richard SmithAug 6, 2025
    How to fix BROVIND CFV4A when the display doesn't light up?
    • J
      James AllisonAug 6, 2025
      First, check that the power cable is properly connected to the mains. Next, open the controller box and ensure the power is correctly connected inside. Also, inspect the fuses on the board to see if they are in good condition. Finally, use a testing device to verify that power is reaching the switch on the controller box.
  • E
    Emily CarterAug 10, 2025
    What to do if BROVIND CFV4A Controller shows a short-circuit at output?
    • M
      Ms. Sara MontgomeryAug 10, 2025
      Turn off the controller immediately and inspect the output for any short-circuits. If no shorts are found, attempt to turn the controller back on. Additionally, check if the vibrator speed was accidentally set to 0 for safety reasons (A0) and reset it.
  • J
    Jason EdwardsAug 14, 2025
    Why is the vibrator not working on my BROVIND Controller?
    • J
      Joseph HuntAug 14, 2025
      Make sure that all parameters are set correctly, including vibration amplitude, frequency, and the activation/deactivation of sensors. Also, verify that the vibrator is properly connected to the power board.
  • A
    anageorgeAug 18, 2025
    What does Supply voltage alarm mean on BROVIND CFV4A Controller?
    • E
      Emily JosephAug 19, 2025
      The supply voltage alarm activates if the supply voltage falls below 50 Volts or exceeds 300 Volts.
  • M
    Matthew TownsendAug 23, 2025
    What to do if BROVIND CFV4A is stopped by a sensor?
    • J
      jasonlynchAug 23, 2025
      Go to the menu for sensor 1 and/or sensor 2 and disable the sensor that is causing the issue.
  • A
    Arthur GrantAug 27, 2025
    How to reset BROVIND CFV4A parameters to factory settings?
    • M
      Michael BergerAug 27, 2025
      The factory-set parameters can be restored by selecting configuration 5 in the “Saving Work Configurations” menu (Menu 40).
  • R
    Renee GarnerAug 31, 2025
    What does SRV02 probe alarm mean on BROVIND CFV4A?
    • M
      michellehicksAug 31, 2025
      This alarm indicates that the probe is set but is not responding. It activates if, with A0 greater than 1.0, As stays at 0 for at least 20 seconds.

Summary

CE DECLARATION OF CONFORMITY

PERSONAL SAFETY RULES

TECHNICAL DATA

INSTALLATION

CONNECTION DIAGRAM

CONTROLLER TERMINAL BOARD MOD. DCFF

CONTROLLER TERMINAL BOARD MOD. CFF15 A

CONTROLLER TERMINAL BOARD MOD. CFF10 A 400 V

REMOTE POTENTIOMETER CONTROL

SPECIAL APPLICATIONS: BALANCE FUNCTION

SPECIAL APPLICATIONS: ELEVATOR UNIT

SPECIAL APPLICATIONS: DISCHARGE UNIT

SPECIAL APPLICATIONS: ALARM-RELATED RELAY

PIECES-COUNTER FUNCTION

PROGRAMMING BOOLEAN FUNCTIONS

MENU 2 CHANGING VIBRATION AMPLITUDE

MENU 3 CHANGING FREQUENCY

MENU 4 CALIBRATED TRACKING

MENU 6 ASSIGNING SENSOR PX1

MENU 7 ASSIGNING SENSOR PX2

MENU 8 EXTERNAL COMMAND 0-10 V; 4-20 mA

MENU 10 AUTOMATIC RUNNING MODE WITH SRV02 PROBE

MENU 14 AUTOMATIC CALIBRATION OF VIBRATOR

CALIBRATION SETTING PROCEDURE

MENU 15 OUTPUT RELAYS

MENU 16 MAXIMUM CURRENT VALUE

MENU 17 SIMULTANEOUS STOP OF BOTH VIBRATOR COMMANDS (LINK TO) AND SYNCHRONIZATION OF TWO COMMANDS (DCFF1 AND DCFF2)

MENU 18 A-MAX SETTING WITHOUT SRV02 PROBE - SETTING A0 100; 1000 STEP

MENU 19 SOFT-START AND SOFT-STOP RAMP

MENU 21 PIECES-COUNTER SETTING AS DEFAULT PARAMETER

MENU 25 VIBRATOR RESONANCE FREQUENCY AND CONDITION SENSORS;RELAIS

MENU 26 PIECES-COUNTER FUNCTION - DISPLAY

MENU 27 PIECES-COUNTER FUNCTION - SETTINGS

MENU 28 TIME-OUT FUNCTION

MENU 30 RESUME FACTORY-SET PARAMETERS - DEFAULT

MENÙ 31 RESET CONTROLLER

MENU 34 MOTOR FUNCTION

MENU 37 Vi SETTING FOR THE CALIBRATION PROCEDURE

MENU 40 SAVING WORK CONFIGURATIONS

MENU 41 RESETTING WORK CONFIGURATIONS

MENU 45 PROGRAMMING LOGIC FUNCTIONS. CREATING, CHANGING AND ENABLING SINGLE BLOCKS

MENU 46 PROGRAMMING LOGIC FUNCTIONS. ENABLING S3 SENSOR (S5 OR S6), ANTIBLOCK FUNCTION AND ACTIVATING PROGRAM

MENU 47 PROGRAMMING LOGIC FUNCTIONS. DELETING ALL THE PROGRAM BLOCKS

MENU 48 PROGRAMMING LOGIC FUNCTIONS. MANAGING TIMER INSIDE PROGRAMS

MENU 50 SET COMMUNICATIONS AND BOARD ADDRESS (RS-485)

MENU 59 BOOTLOADER ENABLE FOR FIRMWARE UPDATING

MENU 70 FULL PASSWORD FOR CHANGING PARAMETERS - PASSWORD 1

MENU 71 PARTIAL PASSWORD FOR CHANGING PARAMETERS - PASSWORD 2

MENU 81 OPEN \ CLOSED LOOP

SRV02 PROBE

MANAGING MULTIPLE CONTROLLERS IN RS-485 NETWORK

MAINTENANCE OF CONTROLLERS

TROUBLESHOOTING