OILING SYSTEM
PRIMING
Observe oil flow through all oil distribution hoses.
Make sure that oil flows through the rear oil distri-
bution manifold to the cylinder block fittings.
Small bubbles are acceptable. Large bubbles
must be eliminated through a continued priming
process.
IMPORTANT: All clear “blue” oil distribution
hoses on the powerhead should fill with oil as the
air is purged from the lines.
Repair any fuel or oil leaks.
The oiling system can also be primed using the
Self-Winterizing feature if diagnostic software is
not available. Refer to STORAGE on p. 91.
1. Crankcase oil distribution hoses (port side) 005348
1. Rear oil distribution manifold 005271
1
1
1. Oil distribution hose
2. Small bubbles
3. Large bubbles
004398