BRP-Rotax
MAINTENANCE MANUAL LINE
REPLACING THE COOLANT
General note
m WARNING
Risk of Burns!
Never open the radiator cap when the cooling system is hot. For safety’s sake, cover
cap with a rag and open slowly. Sudden opening of the cap could provoke the escape
of boiling coolant and result in scalding.
NOTICE
Use only coolant as recommended in the current Operators Manual (OM) and SI-
916 i-001 “Selection of suitable operation fluids“, current issue.
ENVIRONMENTAL NOTE
Protect the environment!
Do not harm the environment by spilling coolant. Dispose coolant in an environmentally
friendly manner.
Instruction To replace the coolant the following steps are necessary:
Figure 7.8: Replacing the coolant
1
Allen screw M6x35 (stainless steel)
2
Gasket ring
3
Water pump
Effectivity: 916 i A / C24
Edition 0/Rev. 1
12–20–00
Page 21
December 01 2023