MAINTENANCE MANUAL LINE
Step
Procedure
1
Open the radiator cap on the expansion tank.
2
Remove the bottom Allen screw (1) (with gasket ring (2) ) of water pump
(3).
3 Drain the engine coolant.
NOTE
If the radiator is located below the engine, also detach the lowest
positioned coolant hose.
4
Fit Allen screw (stainless steel) along with a new sealing ring. Tightening
torque 10 Nm (89 in.lb).
5
If the coolant is being replaced with a different type, (OAT, IAT) the cooling
system must be flushed. See Chapter 12-20-00 section Flushing the cool-
ing system.
6 Refill newly mixed coolant into the expansion tank (highest point of the cool-
ing system). See Chapter 12-10-00 section Coolant check/replenish.
7
Fit radiator cap.
8
NOTE
Run the engine briefly and replenish with clean coolant as required.
12–20–00
Page 22
December 01 2023
Effectivity: 916 i A / C24
Edition 0/Rev. 1