EasyManuals Logo

BRP ROTAX 916 i A Series Maintenance Manual

BRP ROTAX 916 i A Series
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
BRP-Rotax
MAINTENANCE MANUAL LINE
LEAK TESTS
General note
NOTICE
Avoid over-tightening the fasteners. Use a suitable torque wrench for all work.
Instruction To check the following steps are necessary:
Step
Procedure
1
Inspect all fuel lines (steel on engine), their connections and unions.
2
Inspect the fuel lines (steel on engine) for sign of chafing.
CHECKING THE FUEL LINES
General note
See Chapter 05–10–00 section Time limit for parts.
Instruction
CHECKING THE FUEL PRESSURE REGULATOR
General note
Step
Procedure
1 Check the fuel pressure regulator (1) for damages and inspect the general
condition.
2
Perform a leak test (Fuel pumps “ON”).
3
Inspect all connections (2) for secure attachment.
12–20–00
Page 26
December 01 2023
Effectivity: 916 i A / C24
Edition 0/Rev. 1