MAINTENANCE MANUAL LINE
Figure 7.17: Overview
INSTALLATION OF THE MAGNETIC PLUG
Install The following steps are necessary:
Step
Procedure
1 Clean the magnetic plug.
2
Install the magnetic plug. Tightening torque 25 Nm (18 ft lb.)
3 Lock-wire magnetic plug.
Inspect whole system for correct function. Detailed inspection of affected engine
components.
Effectivity: 916 i A / C24
Edition 0/Rev. 1
12–20–00
Page 41
December 01 2023