BRP ROTAX 916 i A Series - Air Intake System and Boost Pressure Control; Air Filter Connection; Turbocharger to Intercooler Connection; Intercooler to Pop Off Valve Connection

BRP ROTAX 916 i A Series
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BRP-Rotax
MAINTENANCE MANUAL LINE
Temperature exceeded briefly
Table 1: Temperature exceeded less than 30 min.
Step
Procedure
1 The whole cooling system must be inspected, repaired or overhauled in ac-
cordance with the BRP-Rotax instructions for continued airworthiness.
2
Inspect all further systems for correct functioning.
3
Carry out detailed inspection of the affected engine components such as:
Leakage check on the cooling system.
Check that the cylinder head attachment is fitted securely. If any of the
cylinder head nuts are loose, proceed as instructed in table 2. “Excess
temperature of over 180 °C (356 °F) and/or for longer than 30 min.“.
Check all coolant fittings (feed/outflow) for secure fit.
Exceeded for longer than 30 min. or more than 135 °C (275 °F)
Table 2: Exceeded for longer than 30 min. or more than 135 °C (275 °F)
Step
Procedure
1 The whole cooling system must be inspected, repaired or overhauled in ac-
cordance with the BRP-Rotax instructions for continued airworthiness.
2
Inspect all further systems for correct functioning.
3 Carry out detailed inspection of the affected engine components.
4
Check compression by carrying out a differential compression check.
5
All cylinder heads and cylinders must be removed and subjected to a de-
tailed check including hardness testing. See Chapter 72-00-00 of the Main-
tenance Manual Heavy (MMH).
05–50–00
Page 24
December 01 2023
Effectivity: 916 i A / C24
Edition 0/Rev. 1