MAINTENANCE MANUAL LINE
NON COMPLIANCE WITH THE COOLANT SPECIFICATION
General note
NOTICE
Use only coolant as recommended in the current Operators Manual (OM).
Non compliance with the coolant specification
Step
Procedure
1 When a different coolant than the former one (conventional coolant) used,
then the coolant system has to be flushed.
See Chapter 12-20-00 section Flushing the cooling system.
2
Fill in expansion tank with new coolant (highest point of the coolant
system).
See Chapter 12-10-00 section Coolant check/replenish.
3 Re-install the radiator cap.
4
NOTE
Run engine for a minute and replenish as required.
Effectivity: 916 i A / C24
Edition 0/Rev. 1
05–50–00
Page 25
December 01 2023