BRP-Rotax
MAINTENANCE MANUAL LINE
Figure 5.17: Special tool
Instruction
NOTE
Perform a visual check of the entire cooling system, check for chafing and coolant
residue.
Step
Procedure
1 Remove one coolant hose at the upper outlet elbow on the cylinder head, hold
the hose up and drain the hose and expansion tank.
NOTE
It is important to have a container of adequate size ready to capture
the coolant before removing the hose.
Effectivity: 916 i A / C24
Edition 0/Rev. 1
05–50–00
Page 27
December 01 2023