BRP-Rotax
MAINTENANCE MANUAL LINE
Figure 5.19: TYPICAL
1
water hose part no. 922250
2
Self compensating clamp 25 part no.
851645
3
Plug
Step
Procedure
3 To the open coolant hose, attach an adapter and connect to a manual
pump or pressure reduction valve. Use the standard spring clamp to se-
cure the hose on the adapter.
Figure 5.20: TYPICAL
1
Hose to expansion tank
2
To pressure source
Effectivity: 916 i A / C24
Edition 0/Rev. 1
05–50–00
Page 29