4.1) Daily checks
Safety
To warrant reliability and efficiency of the engine, meet and
carefully observe all the operating and maintenance
instructions.
m WARNING
Risk of burns and scalds! Hot engine parts!
Conduct checks on cold engine only!
m WARNING
Non-compliance can result in serious injuries or death!
When performing checks which do not require ignition make sure
that the ECU is turned off and the aircraft is secured to prevent un-
wanted engine starts.
NOTICE
If established abnormalities (e.g. excessive resistance of the
engine, noise etc.) inspection in accordance with the relevant
Maintenance Manual is necessary. Do not release the engine in-
to service before rectification.
Coolant level
NOTICE
Operating media must be observed.
Inappropriate coolant quantity can lead to serious engine damage.
The specifications given in Chapter 2.2 must be adhered to
when refilling coolant.
Step Procedure
1 Verify coolant level in the expansion tank, replenish as
required up to top. The max. coolant level must be flush
with the bottom of the filler neck.
2 Verify coolant level in the overflow bottle, replenish as
required. The coolant level must be between max. and
min. mark.
ENVIRONMENTAL NOTE
Protect the environment!
Do not harm the environment by spilling coolant. Dispose coolant in
an environmentally friendly manner.