Step Step Description Procedure
7
Check Caution lamp
state 916 i Type C24
AC-DC converter: 24 V provided
to Terminal X2.C.
Caution Lamp: 14 V Output
(EMS): OFF
Caution Lamp: 28 V Output
(AC): ON
Caution Lamp: Start/Backup
Power: ON
Example
(Symbolic)
Start Power Switch: HOLD
NOTICE
Activate starter for maximum of 10 consecutive seconds only,
followed by a cooldown period of 2 minutes.
Step Step Description Procedure
8 Start Engine HIC B: A connection between
Terminal 4 and Terminal 12 at
916 i Type A, or at 916 i Type
C24 Terminal G and H, actuates
the starter. The connection must
persist until the engine speed
exceeds 1500 rpm.
Example
(Symbolic)
Start Power Switch: HOLD
9 Reduce Throttle
Valve as required
Set linearized throttle position
so that the engine runs on idle.
Example
(Symbolic)
Reduce Throttle.
NOTICE
Increasing engine speed is only permitted at steady oil pressure
readings above 3 bar (43.5 psi).
Page 4-8
December 01 2023
BRP-Rotax Effectivity: 916 i A / C24
Edition 0 / Rev. 1